A
PPENDIX
G
B
72
Service Manual
Ne
w
E
lectronic Cold Platform 2005
Edition
2005.03.25
Language
E
nglish
Sensors Temperature Table:
7. APP
E
NDIX:
Temperatures
Impedance
(degC)
(Ohms)
-30
175199,63
-25
129286,93
-20
96358,16
-15
72500,36
-10
55045,94
-5
42156,97
0
32554,20
5
25338,55
10
19872,17
15
15698,46
20
12487,74
25
10000,00
30
8059,08
35
6534,72
40
5329,87
45
4371,72
50
3605,27
55
2988,68
60
2489,95
65
2084,43
70
1753,04
Temperatures
Impedance
(degC)
(Ohms)
75
1480,91
80
1256,39
85
1070,31
90
915,42
95
785,96
100
677,30
105
585,75
110
508,32
115
442,59
120
386,60
125
338,74
130
297,70
135
262,38
140
231,91
145
205,53
150
182,63
155
162,70
160
145,30
165
130,06
170
116,70
175
104,94
Compressor
Brand
Refrigerant Capacity [ W ]
COP [ W/W ]
GVY 57 AA
ACC
R134a
151
1,33
TWB 1360 MJS
Tecumseh
R600a
155
1,60
GVY 66 AA
ACC
R134a
181
1,33
TWB 1370 MJS
Tecumseh
R600a
170
1,62
NLX 10 KK2
Danfoss
R600a
187
1,87
TWB 1370 MKS
Tecumseh
R600a
170
1,54
TWB 1374 MJS
Tecumseh
R600a
191
1,61
NLX 11 KK2
Danfoss
R600a
205
1,87
Summary of Contents for New electronic cold platform 2005
Page 73: ......