Indesit
Company
27
of 33
Service Manual UK
English
FAULT CODES
U
SER
IN
TER
FA
C
E
POW
ER
BOARD
FILT
ER
FA
N
T
E
RM
INAL
BL
OCK
C
O
IL
14
5 S
C
O
IL
21
0 S
C
O
IL
21
0 L
POW
ER CORD
Hob Status
Codes
Fault Description
Service Steps
Step 2
If fault persists, service visit required.
Step 3
Change user interface.
F / 1
Induction heater
temperature sensor
(NTC) error
Ɣ
Ɣ Ɣ Ɣ
Step 1
Ask the user to switch the power off and on (try to reset the system).
Step 2
If fault persists, service visit required.
Step 3
Check heater temperature sensor (NTC) connections. If OK replace appropriate coil.
Step 4
If fault persists replace Power board.
F / 2
Induction heater
temperature sensor
(NTC) error
Ɣ
Ɣ Ɣ Ɣ
Step 1
Ask the user to switch the power off and on (try to reset the system).
Step 2
If fault persists, service visit required.
Step 3
Check heater temperature sensor (NTC) connections. If OK replace appropriate coil.
Step 4
If fault persists replace Power board.
F / 3
Induction generator
heatsink temperature
sensor (NTC) error
Ɣ
Step 1
Ask the user to switch the power off and on (try to reset the system).
Step 2
If fault persists, service visit required.
Step 3
Check heatsink temperature sensor (NTC) connection. If OK replace Power board.
F / 4
Induction generator
heatsink temperature
sensor (NTC) error
Ɣ
Step 1
Ask the user to switch the power off and on (try to reset the system).
Step 2
If fault persists, service visit required.
Step 3
Check heatsink temperature sensor (NTC) connection. If OK replace Power board.
F / 5
Communication error
Ɣ Ɣ
Ɣ
Step 1
Ask the user to switch the power off and on (try to reset the system).
Step 2
If fault persists, service visit required.
Step 3
Check harness connections. Replace cables if necessary.