- Check the lubrication system
Orientation
Due to different requirements and/or specifications of the respective
manufacturers, be sure to review the respective manufacturer's
documentation!
The principle of open lubrication requires refilling of lubricating oil.
Example: Lubrication system B400 B500 (by BIJUR DELIMON Sure Fire II)
During maintenance of the lubrication system, first perform a visual inspection of all
components involved in lubrication for leaks and their visual condition. The following
components must be examined during maintenance of the lubricating oil system:
- Lubricating oil tank (Z)
- Oil level in lubricating oil tank
- Lubricating oil pump
- Supply and fluid lines
- Pressure gauge (b)
- Metering valves
- Pressure sensors
For all work in connection with operating materials, the information in
the data sheets of the respective manufacturers and the information
in the document Notes on Operating Materials must be observed.
Maintenance Summary - 4.000 Operating hours
54
Maintenance Instructions
B500
DIE219EN - 05.06.2019