Fault
Possible explanation Possible solution
Cable fault/twisted
Check cable see page 28
Panel fault
Check panel see page 27
Decoder circuit fault
Exchange decoder circuit, UXX
Paper handling
Pick up not working
See page xx user manual and page 26 in service
problem
correctly
manual
My own tables
Load them from
a) copy “ownxx.s10” from old to new software
is not on the
old software
b) copy “owntab.evp” from old to new software
new software
Get latest
Take it from our home
a) click on the software you need and select if the
software
page at:
name and position is OK.
http://www.braille.se
b) name EVXXXYYY.EXE where XXX is the
language, YYY is the version no.
c) Move the file (example eveng801.exe) to a
temporary directory (c:\temp)
d) Extract the file (example eveng801.exe) with the
command “eveng801.exe -d”.
This will extract the files and directories on TEMP
directory.
e) Delete source file (example eveng801.exe) on
the temp directory.
f) Run “install.exe”. This will install the software
on directory c:\Everest\ev801 and start up the
program to install on Everest.
g) Next time you start the program run “everest”
on c:\Everest\ev801 and follow the menu
instruction.
No referens puls
Cable faulty or not
Check cable, page 28 and see if LED will be lighted
connected
when moving the printing head
Magnetic sensor
Check sensor function with magnet if the LED
position and function
goes on, if OK move the indicator board and or
twist magnet (inside holder) 180 degrees.
Fault detection
Summary of Contents for EVEREST