Screws on the lubrication system, the connected components, and
the supply lines must be tightened to the manufacturer's specified
torques.
Requirement
The maintenance of the lubricating oil supply requires the following auxiliary or
working equipment:
- Use an ample supply of cleaning rags.
- A sufficient amount of lubricating oil for refilling/changing.
- Replacement filters for lubricating oil tank.
Oil type, specification and quantity as specified in the technical data.
Use only the original filters according to the spare or wear parts list!
Service and maintenance are to be carried out according to the
manufacturer’s specifications.
Procedure
1.
Danger
Pressurized fluids exiting from damaged or incorrectly
installed fluid lines.
General cuts or eye injuries.
Power off the machine and depressurize the hydraulic system
before any maintenance activities. Secure the machine against
being switched on. Wear personal protective equipment.
Check supply and fluid lines (damage and leakage). Supply and fluid lines must
be checked for damage. Pre-damage such as kinks or abrasions should be
logged and replacement should be initiated.
2. Check lubrication pressure and related sensors.
3. Activate lubrication pulse in the control ten times.
4. Monitor the area around the lubricating oil distributor for leakage.
Maintenance Summary - 4.000 Operating hours
97
Maintenance Instructions
G300.2 G320.2 G400.2 G420 G500.2 G520
DIE147EN - 17.08.2022