- Check the pressures on the machine
Orientation
The different pressures of the central lubrication system, hydrostatic system and the
system pressure must be checked regularly.
If there are ambiguities regarding the pressure values, be sure to
consult the fluid diagrams included in the machine documentation/
documentation CD.
Requirement
Pressures on the machines: MS16-6, MS16-6 Plus, MS22-6,
MS22-8, MS32-6.2, MS40-6, MS40-8, MS52-6.3
- Central lubrication system 30 bar
- Hydrostatic pressure 50 bar
- System pressure (hydraulics) accumulator loading operation
92-102 bar
Procedure
1.
The pressure values specified here must absolutely be
observed. If the values specified here differ from the values on
the machine, be sure to contact the INDEX hotline, INDEX
service or an INDEX representative.
Check pressure values
Maintenance Summary - Care activities
11
Maintenance Instructions
MS32-6.2