BBAATTTTEERRYY CCHHAARRGGIINNGG
If your motorcycle will not be used for a period of four (4) weeks
or longer, a maintenance charger should be connected to the
battery using the battery tender plug. The Battery Tender plug is
located under the left side panel. A maintenance charger can be
purchased through your authorized INDIAN MOTORCYCLE dealer.
1. Following the charger manufacturer’s instructions, use a battery
charger designed for use with 12-volt batteries. The charger
should have a maximum charging rate of 1.8 amps. Charge the
battery for approximately 10 hours at a rate of 1.8 amps. If you
use a taper or trickle charger, it will take longer to charge the
battery.
2. After charging the battery, allow the battery to sit 1-2 hours
before checking the state of charge with a DC volt meter. The
charge should be a minimum of 12.5 DC volts. Repeat the
charging cycle if the charge is less than 12.5 DC volts. Replace
the battery if it fails to reach 12.5 volts after the second charge.
BBAATTTTEERRYY CCHHAARRGGIINNGG AANNDD M
MAAIINNTTEENNAANNCCEE
IMPORTANT
Read and follow the safety precautions listed on the battery and
the proper battery charging procedures outlined in the Owner’s
Manual.
AAGGM
M BBAATTTTEERRYY CCHHAARRGGEERR RREECCOOM
MM
MEENNDDAATTIIOONNSS
Indian Motorcycle recommends using the BatteryMINDer® 2012
AGM - 2 AMP battery charger (PN 2830438) to charge and
maintain AGM batteries. The charger can be found on the Polaris
PG&A website.
Batteries that fall below 12.5V run the risk of sulfation, a condition
whereby sulfate crystals form inside the battery and significantly
reduce performance. AGM chargers are designed specifically for
charging AGM type batteries and use high frequency pulses to
partially reverse sulfation.