background image

 2

Safety Information

Table of Contents

Safety Information ....................................2

Work Area Safety ...................................2
Personal Safety  .....................................3
Moving the Compressor .........................3
Air Compressor and 
Pneumatic Tool Safety ...........................4
Electrical Safety .....................................5

Warranty ...................................................7
Pre-Operation ...........................................8

Specifications ........................................8
Duty Cycle ..............................................8
Package Contents ..................................8 

System Components ..............................9
Placement of the Air Compressor ........10
Attaching the Hose  ..............................11
Tool Usage............................................12

Operation.................................................13
Maintenance ...........................................17

General Maintenance ...........................17
Lubrication ...........................................17
Cleaning the Air Filter  .........................17

Care and Cleaning ..................................17
Troubleshooting ......................................18
Service Parts  ..........................................20

This manual contains information that is important for 
you to know and understand. This information relates 
to protecting your safety and preventing equipment 
problems. To help you recognize this information, we 
use the symbols below. Please read the manual and pay 
attention to these symbols.

WORK AREA SAFETY

 

Keep your work area clean and well lit. Ensure 
floors are not slippery from wax or dust. 

 

Operate the air compressor in an open area at least 
18 in. (0.5 m) away from any wall or object that 
could restrict the flow of fresh air to ventilation  
openings. 

WARNING

:

 Do not operate power tools in explosive 

atmospheres, such as in the presence of flammable 
liquids, gases, or dust. Power tools create sparks which 
may ignite the dust or fumes. Keep bystanders, children, 
and visitors away while operating tools. Distractions can 
cause you to lose control.

DANGER

: Indicates an imminently hazardous situation 

which, if not avoided, 

will result in death or serious injury.

 

WARNING

:

 Indicates a potentially  hazardous situation 

which, if not avoided, 

could result in death or serious 

injury.

CAUTION

:

 Indicates a potentially hazardous situation 

which, if not avoided, 

may

 result in 

minor or moderate 

injury.

 NOTICE

:

 Indicates a practice not related to personal injury which, if 

not avoided, 

may

 result in 

property damage

.

WARNING

:

 This compressor is not equipped for, and 

should not be used to supply breathing air. Additional 
equipment would be necessary to properly filter and 
purify the air to meet minimal specifications for Grade D 
breathing as described in Compressed Gas Association 
Commodity, Specification G 7.1 - 1966, OSHA 29 CF9 
1910.134. Compressed Gas Association, 4221 Walney 
Road, Fifth Floor, Chantilly, VA 20151-2923, (703) 788-2700, 
www.cganet.com. Any such additional equipment has 
not been examined and no implication of proper use for 
breathing air is intended or implied.

CAUTION

:

 Always disconnect the air supply and power 

supply before making adjustments, servicing a tool, or 
when a tool is not in use.

Summary of Contents for C041I

Page 1: ...PERFORMANCE CREW COMPRESSOR Questions problems missing parts Before returning to the store call Customer Service 8 a m 6 p m EST Monday Friday PRODUCT SERVICE 888 895 4549 industrialaircontractor com...

Page 2: ...of flammable liquids gases or dust Power tools create sparks which may ignite the dust or fumes Keep bystanders children and visitors away while operating tools Distractions can cause you to lose con...

Page 3: ...andle When the location is reached slowly lower the compressor to the ground Always store the compressor in a horizontal position resting on the rubber bumpers When transporting the compressor in a ve...

Page 4: ...er direct a jet of compressed air toward people or animals Protect your lungs Wear a face or dust mask if the operation is dusty Do not use this air compressor to spray chemicals Your lungs can be dam...

Page 5: ...will not get caught on lumber tools or other obstructions while you are working with a power tool Failure to do so can result in serious personal injury WARNING Check extension cords before each use I...

Page 6: ...accordance with all local codes and ordinances WARNING Improper installation of the grounding plug may result in a risk of electric shock When repair or replacement of the cord or plug is required do...

Page 7: ...or industrial applications Rental applications render this warranty null and void Labor service calls and travel charges are not covered after the first year of ownership on stationary compressors co...

Page 8: ...Lubrication Oil free Input 120V 60 Hz Single phase AC only 15 Amps Minimum branch circuit requirement 15 A Fuse type Time delay Net weight 55 lbs DUTY CYCLE This air compressor pump is capable of run...

Page 9: ...each use F Check Valve not shown When the air compressor is operating the check valve is open allowing compressed air to enter the air tank When the air compressor reaches cut out pressure the check v...

Page 10: ...ronment may cause damage to the unit NOTE Long lengths of electrical wiring could cause power loss to the motor Place the air compressor in a clean dry and well ventilated area The air compressor must...

Page 11: ...sufficient to inflict serious injury WARNING Always wear safety goggles or safety glasses with side shields when operating power tools Failure to do so could result in objects being thrown into your e...

Page 12: ...lting Inflator Brad Nailer Stapler Framing Roofing Nailer Impact Wrench Heavy Duty 1 2 in and 3 4 in Impact Wrench Air Ratchet Recommended Tool Use Tool Cutting Drilling Surface Prep Painting HVLP Pai...

Page 13: ...ssure must never exceed the maximum pressure rating CAUTION Risk of unsafe operation Compressed air from the unit may contain wa ter condensation and oil mist Do not spray un fil tered air at an item...

Page 14: ...to heed this warning could result in death or serious personal injury The safety valve automatically releases air when the receiver pressure exceeds the preset maximum Check the valve before each day...

Page 15: ...injury NOTE Always use the minimum amount of air flow with the pressure regulator knob Using a higher pressure than needed will drain air from the tank more rapidly and cause the unit to cycle on mor...

Page 16: ...oolers dryers This condensate contains lubricating oil and or substances which may be regulated and must be disposed of in accordance with local state and federal laws and regulations NOTE If the drai...

Page 17: ...er 2 from the air filter housing 3 Blow compressed air through the air filter for 10 15 seconds using an approved OSHA nozzle 1 2 3 WARNING When servicing use only identical Industrial Air Contractor...

Page 18: ...ntil the compressor restarts automatically The motor hums while running slowly or it does not run at all There is low voltage from the power source Call an electrician The wrong gauge wire or length o...

Page 19: ...ution and tighten The drain valve is loose or open Tighten the drain valve The check valve is leaking Bring the compressor to a service center There is excessive moisture in the discharge air There is...

Page 20: ...20 Service Parts C041I AIR COMPRESSOR 2 22 23 24 25 26 27 28 29 0 5 21 30 31 32 33 34 35 35 36 37 37 37 38 38 39 40...

Page 21: ...Cord E106629 11 Filter Assembly E106632 12 Shroud Left E109737 13 Shroud Right E109317 14 Rocker Switch E106633 15 Pump E109720 16 Drain Valve E109739 17 Gauge Tank E107854 18 Gauge Regulator E107855...

Page 22: ...older E109472 37 Screw 250 20 X 75 E106611 38 Screw 10 24 X 563 E106614 39 Screw 10 14 T20 E106646 40 Tank Top Panel E109742 41 Label Warning E109741 42 Label Warning Drain Tank E109313 43 Label Hot S...

Page 23: ...ervice Parts continued PUMP MOTOR ASSEMBLY Item Number Description Part Number 1 Pulley E106663 2 Belt E106664 3 Fan E106665 4 Screw E106666 5 Flywheel E106667 6 Screw E106668 7 Screw kit of 4 E106669...

Page 24: ...issing parts Before returning to the store call Customer Service 8 a m 6 p m EST Monday Friday PRODUCT SERVICE 888 895 4549 industrialaircontractor com Retain this manual for future use Document Numbe...