IDS 410/422 User's Manual
55
Error Messages
Error No. Description
Err 1
Keyboard error. Occurs during power up while a key on the keyboard is being
pressed or one of the remote switch inputs is activated.
Err 2
Restart Trap. The microprocessor accessed nonexistent memory location.
Usual cause is A/C power "glitch" or static electric discharge.
Err 3
Watchdog Timeout. The weight display has not been updated within the
watchdog time-out period. Usual cause is A/C power glitch or static electric
discharge.
Err 4
Battery Error. (Optional) battery voltage level was below 2 V when the
410/422 was powered off.
Err 5
Earom memory error. A checksum error has occurred when reading the
configuration earom memory. Check calibration parameters and rewrite the
earom memory. If error continues, replace earom (U12).
Err 5
Earom Timeout, unable to write to the earom memory.
Err 6
Ram memory error. A ram memory error has occurred. Replace U5 if error
continues.
Err 7
The A/D converter is "locked up". Check load cell wiring.
Err 8
Negative deadload error.
Err 9
Count-by error. The entered value is outside the scale count-by set during
calibration.
Err 10
Push button zero error.
Err 11
A to D convertor not working. Check load cell wiring.
Err 12
Negative deadload. Check loadcell wiring. Enter a deadload offset in
configuration parameter 19.
Err 14
Page Format line length error. The page format output exceeded the maximum
line length.
Err 15
The function selected is locked. Switch S1 on the IDS 410/422's circuit board
locks and unlocks configuration parameters.
Err 16
Scale Basic Stack Overflow. Too many setpoints in user function running
simutainuously.
Err 18
Referenced a Function Instruction that does not exits.
Err 21
ID not found.
Err 22
Scale Basic Prompt error.
Err 23
ID memory full.
Err 24
Link list error.
Error OL Calibration error or scale is over-loaded (above scale capacity).
undEr
Calibration error or scale is under-loaded (below readable weight).
SuSPEn Scale Basic execuded a RESUME instruction without a corisponding
SUSPEND instruction.
Summary of Contents for IDS 410