24
Table 5.4 Sensor specifications, Hydrogen Sulfide
H2S for Tango TX2; part number 17160207
Properties
Category
Toxic
Technology
Electrochemical
Installation location
1 or 2
Operating conditions
a
Temperature range
-40 to +50 °C (-40 to +122 °F)
RH range
15-95%
Performance
Sensitivity
Measurement range
0
–
500 ppm
Measurement resolution
0.1 ppm
Accuracy
b
Calibration gas and concentration
25
ppm
H
2
S
Accuracy at time and temperature of
calibration
± 5%
Accuracy over sensor’s full temperature
range
± 15%
Response Time
T50
8 s
T90
20 s
a
During continuous operation.
b
Apply when the instrument is calibrated using the stated calibration gas and concentration; accuracy is equal to the stated percentage
or one unit of resolution, whichever is greater.
Note
: See
for supplemental information about sensor types and gases.