Registers
Description
Default
Min
Max.
R/W
7536
MIN_VOLT_SUPPLY_FAN
(see table pag.
40
)
(Note2)
I62
0
0
I63
R/W
7537
MAX_VOLT_SUPPLY_FAN
(see table pag.
40
)
(Note2)
I63
100
I62
100
R/W
7538
SPEED_1_MODULATING
(see table pag.
40
)
I64
10
0
I65
R/W
7539
SPEED_2_MODULATING
(see table pag.
40
)
I65
65
I64
I66
R/W
7540
SPEED_3_MODULATING
(see table pag.
40
)
I66
100
I65
100
R/W
7541
FAN_START_BOOSTER
(see table pag.
40
)
0=Fan starts at set speed
1=Fan starts at maximum speed for 1 s and then goes to set speed
I67
1
0
1
R/W
7542
AIR_DESTRAT_ACTIVATE
(see table pag.
40
)
0=OFF
1=ON
2=ON in heating only
3=ON in cooling only
I68
1
0
3
R/W
7543
TIME_DELAY_ON_DESTRAT
(see table pag.
40
)
I69
1
1
5
R/W
7544
TIME_DELAY_OFF_DESTRAT
(see table pag.
40
)
I70
10
1
60
R/W
7545
MAX_HOUR_FAN_RUN
(see table pag.
40
)
I71
2000
0
9990
R/W
7546
VISU_TYPE_FIST_DISP
(see table pag.
40
)
0=Internal sensor temperature
1=Temperature of external sensor
AI1
2=Temperature of external sensor
AI2
3=Temperature of external sensor
AI3
4=Zone 1 control temperature
(paragraph 13 on page 51)
5=Actuator 2 zone control temperature
(par. 13 on page 51)
6=Actuator 3 zone control temperature
(par. 13 on page 51)
7=Actuator 4 zone control temperature
(par. 13 on page 51)
8=Control temperature for all zones, alternately
9=Internal humidity reading (for
FH-xxxSH1
models only)
10=thermal actuator 1 operating setpoint (paragraph 15 on page 53)
11=operating setpoint thermal actuator 2 (paragraph 15 on page 53)
12=operating setpoint thermal actuator 3 (paragraph 15 on page 53)
13=operating setpoint thermal actuator 4 (paragraph 15 on page 53)
14=Control setpoint for all zones, alternately
15=Dew point
0$67(5FRQWUROOHUÀRZWHPSHUDWXUH
17=Value of 0..10 V output
AO1
(V)
18=Value of 0..10 V output
AO2
(V)
19=Value of 0..10 V output
AO3
(V)
I72
0
0
19
R/W
7547
VISU_TYPE_SECOND_DISP
(see table pag.
40
)
0=Internal sensor temperature
1=Temperature of external sensor
AI1
2=Temperature of external sensor
AI2
3=Temperature of external sensor
AI3
4=Zone 1 control temperature
(paragraph 13 on page 51)
5=Actuator 2 zone control temperature
(par. 13 on page 51)
6=Actuator 3 zone control temperature
(par. 13 on page 51)
7=Actuator 4 zone control temperature
(par. 13 on page 51)
8=Control temperature for all zones, alternately
9=Internal humidity reading (for
FH-xxxSH1
models only)
10=thermal actuator 1 operating setpoint (paragraph 15 on page 53)
11=operating setpoint thermal actuator 2 (paragraph 15 on page 53)
12=operating setpoint thermal actuator 3 (paragraph 15 on page 53)
13=operating setpoint thermal actuator 4 (paragraph 15 on page 53)
14=Control setpoint for all zones, alternately
15=Dew point
0$67(5FRQWUROOHUÀRZWHPSHUDWXUH
17=Value of 0..10 V output
AO1
(V)
18=Value of 0..10 V output
AO2
(V)
19=Value of 0..10 V output
AO3
(V)
20=Current hours:minutes
21=Total hours of fan 1 operation
22=Total hours of fan 1 operation
23=Value of input
AI3
FRQ¿JXUHGDV9LQSXW
24=display B off
I73
19
0
24
R/W
7548
FUNCTION_RIGHT_KEY
(see table pag.
40
)
0=Local season changeover if a season changeover contact is not used.
1=Timer extension zone 1
2=Timer extension zone 2
3=Timer extension zone 3
4=Timer extension zone 4
5=Operating mode (normal, using the time slots or “non-occupied holiday”)
I74
1
0
5
R/W