Safety
sales@romanoff.com | www.romanoff.com
2019-10-16
2
–6
2.5
Safety advices
Check always the condition of the system before you switch on the
system. Examine the supply pipes and insulations if there are leaks
and damages. Operate the system only if it is in proper and faultless
shape.
Operate the system never:
if there are malfunctions,
if it is showing damage or
after heavy transportation stress.
The system has to be constantly controlled when running to be able
to recognize and avoid dangerous situations. The system may not run
if it is unsupervised.
Do never change, remove or close the safety valves inside the ma-
chine.
Danger!
Danger to life because of strong electromagnetical fields
(induction). For persons with pacemaker it is not allowed
to approach or to be near to the machine.
Danger!
Danger to life are caused also by the fact that very hot and liquid
metals solidify in cold liquids. In this case, may arise physical and
chemical reactions that have to be previously analysed by the user.
During this it can emerge physical and chemical reaction, which is to
be evaluated by the operator.
Warning!
Risk of burning on hot surfaces and hot metal
(until ~ 2000 °C). Wear always personal protective
equipment when you work with the machine.
Utmost caution during using graphite crucibles and
graphite moulds. The heat of these parts is only visible
when the temperatures are over 500 °C.
Warning!
Maintenance and servicing of the machine only when the system is
disconnected from the mains supply (Pull out mains plug).
Advice!
Don’t disconnect mains plug, while machine is running or in standby.
Switch off for pulling out or putting in mains plug.