C-COM Satellite Systems Inc.
Page 68 of 164
M18C -
iNetVu
®
1.8m Fixed Motorized (C – Band circular)
M18D -
iNetVu
®
1.8m Fixed Motorized (X – Band circular)
M12A -
iNetVu
®
1.2m Fixed Motorized (Ku – Band)
M121A -
iNetVu
®
1.2m Fixed Motorized C-COM version (Ku – Band)
M125A -
iNetVu
®
1.2m Fixed Motorized C-COM version (Ka – Band)
N18A -
iNetVu
®
1.8m Drive-away Platform (Ku– Band)
N18B/E -
iNetVu
®
1.8m Drive-away (C – Band Standard Linear/INSAT)
N18C -
iNetVu
®
1.8m Drive-away (C – Band Circular)
3 - TO (Mechanical Offset in Polarization Assembly)
This field allows the user to place a fixed offset for the target polarization angle.
This value could make up for any noticeable mechanical offsets in the
polarization assembly of the iNetVu platform between -5º to +5º.
e.g. 1) Calculated Target Polarization Angle = 10º
TX_O = +3º
The iNetVu system will position @ 7º when pointing
e.g. 2) Calculated Target Polarization Angle = 10º
TX_O = -3º
The iNetVu system will position @ 13º when pointing
4 -
Platform Serial Number
The user must enter the last four or five-digits of the platform serial number
located next to the connector plate on the iNetVu
®
Mobile Platform. If platform
and controller were purchased as a set, the number has been preconfigured for
you.
Fig. 48:
iNetVu
®
Platform Identification Tag
5 –
Platform
Version Number
The user must select the platform version type to ensure the correct configuration
parameters and settings are referenced when operating the system. The platform
version when selected will differentiate the sensor and other hardware configuration on
New Generation platforms which may affect the operation.