tina29d2-b (2004-10) VSA100A.ga
Electrical connection
standard cable 3 m
Vacuum connection
DN 16 KF
Protection type
IP44
Materials in contact with the medium
Stainless steel 1.4305, 1.4310
Stainless steel 1.4300 PTFE coated
EPDM
Internal volume
2 cm
3
Weight
315 g
1.3
Function
At a differential pressure of 6 mbar when pumping down
or 3 mbar when venting below atmospheric pressure, an
elastic diaphragm actuates a changeover contact which
in turn may be used to directly switch any ancillary
equipment. The electrical connections are placed under
a plastic cover.
1.4
Equipment
1.4.1 Scope of delivery
Vacuum Switch VSA100A
complete with cable, 3 m
Part Number 399-001
Operating Manual
tina29d2
tina29d2-b (2004-10) VSA100A.ga
12
12
Electrical connection
standard cable 3 m
Vacuum connection
DN 16 KF
Protection type
IP44
Materials in contact with the medium
Stainless steel 1.4305, 1.4310
Stainless steel 1.4300 PTFE coated
EPDM
Internal volume
2 cm
3
Weight
315 g
1.3
Function
At a differential pressure of 6 mbar when pumping down
or 3 mbar when venting below atmospheric pressure, an
elastic diaphragm actuates a changeover contact which
in turn may be used to directly switch any ancillary equip-
ment. The electrical connections are placed under a pla-
stic cover.
1.4
Equipment
1.4.1 Scope of delivery
Vacuum Switch VSA100A
complete with cable, 3 m
Part Number 399-001
Operating Manual
tina29d2