background image

Get All

 

 downloads all events to screen.

 

Stop

 - stops download of events

 

“+”

 - press + to expand the view events

 

Note: If the event log has been cleared or if the user believes there are events not being displayed, enter the number 
4000 to download the full event file. Enter 4096 for settings and events. If less than 4000 events have been logged on the 
controller, some events will be not be clear. For example, numerical values may display random letters.

 

File Operations (on the Home screen):

  Allows for the management and transfer of 

even

ts and settings to a removable USB memory device or to the Tapper’s internal 

memory.                

 

Home: 

brings the user back to the home screen

 

File:

  The file menu is used to transfer settings, events and reports to and from 

the controller.  The user 

can save data to the Tapper’s internal memory or an 

external USB.

 

Analyze

:  Allows the user to review an Event Summary and view a graph of the 

data.  Graphs feature is a trial.  Graph may not always display properly.

 

Events:

 is the standard events menu described above. 

 

Saving a Report:

 

With thumb drive installed in a computer, setup a folder (directory) to receive data.  

Make a folder named Aquaworx. In that folder make three folders. Name them;  EVT,  
RPT,  SET. This can also be done by inserting the thumb drive into the Tapper then go to;   

http://dlc.com/prepusb.html

  in the address bar. 

Insert thumb drive in USB slot on Tapper Unit.  Tapper will beep. 

Go to Event page and “Get All” then  “Analyze” 

 

Next go to 

File Page and Select External USB, File Type; “Report”   tap “Save”.

 

Remove thumb drive, insert in computer, Report will come up as a text file. Text file can 
then be opened in a document file (Libre office, Word) or converted to a spreadsheet file. 

 

Warning: Risk of fire! Battery can explode or leak and cause injury if handled improperly.  
Do not install backward, disassemble, crush or expose to high heat or fire.

 

 

Use only li-ion 3.7-volt rechargeable battery size 14500.

  Replacements are available from ISI. 

Use of the wrong battery may cause personal injury or damage to the unit. 
 

 
 

  

 

Summary of Contents for Aquaworx Tapper

Page 1: ...a few seconds you will hear a beep 2 After powering up the Tapper please wait through the start up sequence 40 seconds Once the light is on next to Wi fi and DLC you are ready to communicate with the panel 3 Connect the Tapper to the circuit board in the Aquaworx IPC Panel using the provided rj45 cable Connect 1 Go to available Wi Fi networks on your Laptop tablet or cell phone Find and select the...

Page 2: ...un time on pump since installation Doses Counter displays the total number of normal doses Vetos counter displays the total number of veto doses Status Displays the current status of the panel and provides manual operation Status Panel status Man on man off Idle waiting pumping On Time Counts in minutes when pump is running Off time Counts in minutes when pump is in off cycle Inches Displays curre...

Page 3: ...al This feature is used to help maintain a time dosed regime in periods of peak volume Auto Clear the number of On Off cycles the panel will complete after pumping below the start level Typically Auto Clear is set to 1 dose This ensures that occasionally the liquid level will drop below the bottom of the transducer bell When programmed for very small doses or with larger tanks it may take multiple...

Page 4: ... Graphs feature is a trial Graph may not always display properly Events is the standard events menu described above Saving a Report With thumb drive installed in a computer setup a folder directory to receive data Make a folder named Aquaworx In that folder make three folders Name them EVT RPT SET This can also be done by inserting the thumb drive into the Tapper then go to http dlc com prepusb ht...

Reviews: