Power Supply and Control
The XC2200 can run from a single external power supply. The core supply voltages can
be fed in from an external Voltage Regulator (VR) or can be generated by on-chip
Embedded Voltage Regulators (EVRs).
Power Domains
To significantly reduce the consumed leakage current special power states directly
considered for power saving are implemented. The configuration of the power supply
depends on the Operating Modes described in the Programmer’s Guide.
The I/O part is divided in two parts DMP_A and DMP_B. DMP_A contains all ADC
related I/Os and DMP_B the remaining system and communication I/Os.
The major part of the on-chip logic is located in an independent core power domain
(DMP_1). A second, smaller power domain (DMP_M), marked grey in the figure below,
controls wake-up mechanism and other important device infrastructure plus a Standby
RAM (SBRAM). The DMP_M and/or DMP_1 can be either switched off, i.e. disconnected
from power by disabling the respective EVR or lowered to 1.0 V.
Figure 6-17 XC2200 Power Domain Structure
DPRAM
CPU
PM
U
DMU
EBC
LXBus Control
External Bus
Control
DSRAM
PSRAM
OCDS
Debug Support
Peripheral
Data Bus
BLOCKDIAGRAM_MR
Program
Flash
LXBus
Power
Control GSC
Reset
Control
Clock
Control
PLL
OSC_
WU
OSC_
HP
ESR
WDT
Temp.
Comp.
SCU
IM
B
Stand-By RAM
PEC/
INT
LXBus
Ports
ERU
ADC
x
GPT
CC
x
CCU
6x
USIC
x
Multi
CAN
MP
U
RTC