Application Note
28 of 36
002-34970 Rev. **
2022-05-03
Foreign object detection tuning guide for wireless power transmitters
Applicable for WLC ICs
FOD parameter tuning
S. no.
Parameter
Description
20
EPP power loss FOD threshold no retries
and power latch (mW)
Maximum power loss threshold for 15W EPP
mode of operation. See Case 2.
Default value is 2000mW.
21
EPP FOD retry count
Count for Power Recycle after FOD for EPP 15W
device.
Default value is 1 count.
22
EPP Power delivery retry count before
stopping power delivery
Count for power cycle after FOD for EPP 15W
device.
Default value is 1.
23
PPDE power loss FOD threshold (mW)
Threshold for a likely FO presence for PPDE
Default value is 750mW.
24
PPDE power loss FOD threshold no retries
and power latch (mW)
Threshold for a certain FO presence for PPDE
Default value is 2000mW.