Application Note
32 of 36
002-34970 Rev. **
2022-05-03
Foreign object detection tuning guide for wireless power transmitters
Applicable for WLC ICs
Appendix II
–
Received power offset
Appendix II – Received power offset
Note:
This section is compliance tester-specific and may be subject to change. Please contact sales support for
more details.
Received power offset is a modifiable parameter in the Power Transfer Phase setting in Advanced mode of the
Qi compliance tester (see
).
Figure 24
Received Power Offset in Advanced mode
The value of Received Power Offset in the Advanced mode operation determines the accuracy of the system
power loss coefficients used to calculate the system power loss. The default values of received power offset are
different for Qi 1.2 and Qi 1.3 and may vary for Qi compliance tests as well as guaranteed power (GP) tests. The
following table provides the default values for Received Power Offset (mW) for various Qi versions and GP tests:
Table 5
Receiver power offset observed in compliance tool
TPR
Qi 1.2
Qi 1.3
GP test
TPR#MP3
705
175
705
TPR#7
335
335
335
TPR#5
35
35
35
Please use the GP values as offset for calibration operation.