Data Sheet
143
Rev. 1.00
2017-07-31
TLE9262BQXV33
Serial Peripheral Interface
Notes
1. A timer must be first assigned and is then automatically activated as soon as the on-time is configured.
2. If cyclic sense is selected and the HS switches are cleared during SBC Restart Mode, then also the timer
settings (period and on-time) are cleared to avoid incorrect switch detection.
3. In case the timer are set as wake sources and cyclic sense is running, then both cyclic sense and cyclic wake
will be active at the same time.
TIMER1_CTRL
Timer1 Control and Selection (Address 000 1100
B
)
POR / Soft Reset Value: 0000 0000
B
;
Restart Value: 0000 0000
B
7
6
5
4
3
2
1
0
Reserved
TIMER1_
ON_2
TIMER1_
ON_1
TIMER1_
ON_0
Reserved
TIMER1_
PER_2
TIMER1_
PER_1
TIMER1_
PER_0
r
r
rwh
rwh
rwh
r
rwh
rwh
rwh
Field
Bits
Type
Description
Reserved
7
r
Reserved, always reads as 0
TIMER1_
ON
6:4
rwh
Timer1 On-Time Configuration
000B , OFF / Low (timer not running, HSx output is low)
001B , 0.1ms on-time
010B , 0.3ms on-time
011B , 1.0ms on-time
100B , 10ms on-time
101B , 20ms on-time
110B , OFF / HIGH (timer not running, HSx output is high)
111B , reserved
Reserved
3
r
Reserved, always reads as 0
TIMER1_
PER
2:0
rwh
Timer1 Period Configuration
000B , 10ms
001B , 20ms
010B , 50ms
011B , 100ms
100B , 200ms
101B , 1s
110B , 2s
111B , reserved