TD-TM102 Rev R
|
2018-06-25
9 (11)
Infinera Proprietary and Confidential
9
Technical Data
Table 5 Mechanical & Electrical Data, TM-102
Parameter
Value
Height
1U / 44 mm
Depth
249mm excl mounting brackets
Width (excl. mounting brackets)
448mm
Primary Power
DC-inlets. Redundant. Fixed.
Cooling
Fixed fans
Mounting
ETSI, 19”
Fiber management
No
LAN/Mgmt connections
RJ45
Primary power range AC
External AC/DC-converter
100-240VAC, 50/60Hz, 1.1A Class I
Primary power range DC
48VDC (40.8 – 57.6VDC), 3A Class III
Max Inrush current @ -48VDC
1,9A / 30ms
Max power at AC powering
55 W
Max power at DC powering
50 W
Max power consumption in card cage
~45W
Weight DC-powering:
~3,4 kg
DC cable size
1.5 mm
2
(connector limit)
Standard 1,0 mm
2
Operating conditions
ETSI EN 300 019-1-3 class T3.1
9.1
Environmental conditions
Configurations with the TM-102 chassis supports ETSI EN 300 019-1-3 T3.1 (+5 to +40°C
(+41 to 104°F)) and ETSI EN 300 019-1-3 T3.1E (–5 to +45°C (+23 to 113°F)). See also “XTM
Series Overview Description” within the System Manual.
9.2
Revision Data
A TM-102 chassis has an order level that includes mechanics, cables etc. The table shows re-
vision data on the basic card cage mechanics.
Table 6 Revision Data
Ordering code
Product number
Rev
Introduced
Release
TM102-DC
M102/ENC
R1A
R10.0
1st released version
October 2015: Product in EOL-Effective, i.e. no longer or-
derable. Replaced by TM-102/II. See 100025-PTN00018.
TM102-PAS-L-S
M102/PAS
R1A
R12.0
1st released version
R1B
R24
Change in thickness of metal
TM102-PAS-3S
M102/PAS/3
R1A
R15.0
1st released version
R1B
R24
Change in thickness of metal
Note that orders are placed on specific sales objects, listed in section 9.3
.