Hybrid DVR User Manual
TEC-VS-219-1905-V01
Choose one of the rule numbers. It is the number of SOD area. Maximum 4 areas can be set for SOD
function.
To enable the detection in
Rule Switch
Choose a
Rule Type
.
Legacy: DVR will only detect the left-over objects;
Lost: DVR will only detect the lost objects;
Legacy and Lost: DVR will detect both left-over and lost objects.
Use the mouse to click 4 points in the camera picture to draw a virtual region. The shape of the region
should be a convex polygon. Concave polygon will be not able to save.
Click
Save
to save settings.
To adjust the size of the region, click the red box in the region, the borders of the region will be
changed to red color. Press the mouse left button to move the whole region, or drag the corners to
resize the region.
To remove one of the regions from the camera picture, click the red box in the region and then click
Remove
button. Click
Remove All
will delete all regions.
Note:
1) The area for detection shall be greater than or equal to the size of the detected object, such as the
detection of a white bottle.
2) The detected object cannot be covered.