background image

Infinition Inc.   Rev. 02 

 

 
 

10

4.3.5.1

 

Managing results in Review mode 

 

First, make sure you are in the Review Mode as show above, then: 

 

 

To navigate through the results, use the UP and DOWN arrows. 

 

To make a new Series press the Series 

  button and confirm your choice by using the up/down 

arrows and pressing Enter. 

 

To delete a series press the Delete 

 

button and confirm your choice by using the up/down arrows 

and pressing Enter.  

WARNING: this action is irreversible.

 

 

To access individual shots, first select your series with the arrows, then press Enter  

 

 

To delete a Shot press the Delete 

 

button and confirm your choice by using the up/down arrows 

and pressing Enter. 

WARNING: this action is irreversible.

 

 

4.3.6

 

Screensaver 

 

If the display screen turns off, press any key, except power, to turn the display on. 

 

4.3.7

 

Battery Installation 

 

Install six (6) AA alkaline battery in the battery compartment. When not in use remove the batteries. To 
conserve your batteries you should keep the Armed time setting at a minimum and the Screensaver time at a 
minimum. It is advisable to have a spare set of batteries available.  
 
* The unit can also be powered by a USB power supply through the USB port.  5V @ 1A is required. 

 

4.3.8

 

Memory 

 

The use of SDHC cards of known brandings is recommended.   Regular SD card, SDXC and others may fail 
to work in the device. 

 

With the unit turned off insert a SD Card with sufficient memory to record the shots you anticipate taking. 
Should you need to remove the SD Card always turn the power off prior to removing the SD Card. Make 
sure the SD Card is clean and free of debris before inserting. Keep the SD slot cover in place to protect it 
from dust, moisture, etc. 
 
If no SD Card is inserted, the system will record the shots in its internal memory.  As this memory space is 
limited, you can only get advanced reports published on an SD card. 
 

4.3.9

 

USB Port 

 

Make sure the USB port is clean and free of debris.  Keep the USB cover in place to protect it from dust, 
moisture, etc. 

 

4.3.10

 

Downloading Data 

 

* You need an SD card in your device before you can download any data. 

 
You can access the data by connecting a USB cable on the LabRadar and to a computer.  The computer 
should recognize the LabRadar as a Mass Storage Device and display the files available on the SD Card.  
Alternatively, the user can turn OFF the LabRadar and remove the SD card to read it in a memory card 
reader (Fastest). 
 
The data needs to be recorded while the SD card was in the device to be accessible later by USB. 

Summary of Contents for Labradar

Page 1: ...ease contact Canadian customers should return to Infinition Inc 2455 de l Industrie Trois Rivieres QC Canada G8Z 4T1 techsupport mylabradar com 316 866 2525 All others should return to TCK LLC 8221 W Meadow Pass Ct Wichita KS 67205 U S A techsupport mylabradar com 316 866 2525 ...

Page 2: ...may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or...

Page 3: ...ur LabRadar Upon firing the shot the radar unit will begin transmitting and will continually track the bullet reporting numerous velocities along its path Based upon the large amount of data gathered from the tracked projectile the muzzle velocity can also be determined 2 Microwave Safety Warning 3 Specifications Description Specification Power Requirement 6 AA Batteries or USB powered 800mA Frequ...

Page 4: ...t transmitting Red Unit is powered On transmitting Armed Flashing Red Unit is powered On transmitting system will stop transmitting shortly within 10 seconds if no trigger is detected 4 1 Buttons definition The LabRadar is equipped with an array of buttons each used for a different function 1 Display Parameters 2 Series 3 Delete 4 Up 5 Enter 6 Down 7 Power 8 Arm 9 SD Card 10 USB Connector External...

Page 5: ... the LabRadar Each velocity range is specified to weapons type as a reference Rifle 300m s to 1050m s Handgun 75m s to 525m s Archery 20m s to 225m s Set proj offset Input the distance between the gun s muzzle and the side of the radar to optimize the precision of the measurements Set distances Specify the distances at which the velocity measurements are made Dx1 to Dx5 Proj Weight Set the project...

Page 6: ...e Radar In order to use multiple radars close to each other use a different frequency for each radar Failure to do so may result in bad operation of the radar For contiguous Labradar try to use at least a 2 channels separation TX Power US Canada Australia models only Select the LabRadar transmitting power High or Low While High power offers a longer range measurement range the low power mode can b...

Page 7: ...n the radar look through the sighting notch located in the top center of the unit and aim the radar at the target that you will be shooting at Make sure it is in a stable position to insure that there is no movement after you align it with your target Place the LabRadar in a position where it will not be impacted by ejecting cartridge cases muzzle debris blast or other items The LabRadar SHOULD NO...

Page 8: ...disarmed automatically as it has not received a Trigger for a while This time corresponds to the Arm Time in the Configuration Menu See Section 4 2 Once the light begins to flash you will have 10 seconds to fire the shot before the Arm Time has expired After a successful shot the Shot number will be increased by 1 and the resulting measurements will be displayed on screen 4 3 3 Last shot review mo...

Page 9: ...shot on screen The screen displayed is identical to the Last shot review 4 3 5 Review Mode Blue indicator The review mode allows the user to navigate through all the results available in the LabRadar When it it turned ON the LabRadar starts in Review mode To access the Review mode from the Last shot review or the Armed view the user should hold the arm button for 2 seconds The Review mode display ...

Page 10: ...power supply through the USB port 5V 1A is required 4 3 8 Memory The use of SDHC cards of known brandings is recommended Regular SD card SDXC and others may fail to work in the device With the unit turned off insert a SD Card with sufficient memory to record the shots you anticipate taking Should you need to remove the SD Card always turn the power off prior to removing the SD Card Make sure the S...

Page 11: ... of the LabRadar that indicates the battery condition If the battery voltage becomes insufficient to operate the system will shut down Bluetooth Indicator There is an icon on the display of the LabRadar that indicates when a Bluetooth connection is active When there is no Bluetooth connection the icon is not shown on screen Radar Signal Strength Indicator The signal strength indicator is located o...

Page 12: ...USB Connector Specification Connector type USB micro Type A female on unit 7 SD Card Connector Connector type SD Card Socket Standard 8 Trigger Input Connector Connector type Stereo 1 8 stereo audio jack with specific pinout Do not connect headphones Safety Information 1 Always keep the weapon pointed in a safe direction and keep your finger off the trigger until you are ready to shoot 2 Firearms ...

Page 13: ...s entered in the LabRadar configuration match you installation Due to microwaves signals nature range performance of the LabRadar can differ depending on the environmental conditions Temperature Humidity Particles in the air Signal reflection on the ground trees wall and any other surface in the line of fire Frequency channel used for transmission Etc In addition the projectile s characteristics w...

Page 14: ...manship found upon examination by INFINITION INC This warranty does not cover any failures caused by abuse mishandling failure to the follow the operating instructions alteration s or accident Damaged caused by bullet impacts gunfire debris or ejecting materials are not covered by warranty To make a claim under this warranty the original purchaser must return the product to the address shown below...

Page 15: ...Infinition Inc Rev 02 15 CONSULT WITH PROPER GOVERNMENT AUTHORITIES BEFORE EXPORTING or IMPORTING THIS ITEM ...

Page 16: ...r to the side of the unit The display goes black while shooting Adjust the Screensaver time in the preferences menu to a longer time Touch any button except Power or Arm to disengage the Screensaver The Labradar will turn OFF and back ON when armed Check the batteries level The Labradar will not power ON Check the batteries replace if needed Check the USB connection if power supply is powered on P...