background image

9

10

 Remove the chair body from the box. This should include the chair body, back

     seat

 

pad

,

 pillow

,

 power

 

cord

,

 remote control and control pocket. This

 

requires

 

at

 

least

     three

 

people

.

 While two

 

people

 

hold

 

the

 

seat

 

frame

 

on

 

the

 

two

 

sides,

 

the

 

third

     person should

 

hold

 

the

 

backrest, working together to lift the chair out slowly.

     See below:

 

Remote Control Pocket

Remote Control

Two people grasp left 
and right metal seat
frame, while the other
holds the backrest,
slowly removing the
main body of massage
chair from the box .

To install the leg rest onto the main body: 

 Unscrew the bolt on the hanger of the leg rest. 

 Connect the leg rest air hose to the corresponding air nozzles of the main body tightly.

 Plug the two power cables into the socket securely. Be careful to match the color and 

direction: black to black, white to white. 

 Raise the rotation shaft board on the hangers, 

lift the leg rest with your hands, place the rotation shaft into hangers on main body, then close 
the rotation shaft board. 

 Screw it back tight. 

 Connect the leather leg rest cover to the 

seat with the Velcro piece.

Black

White

Electric Power Cable

Head Cushion

Installation

Installation 

(

1

)

Installation 

(

2

)

Installation

Installation

Installation

Back Seat Cushion

Step 1.  How to Move the Chair

Right Armrest

Left Armrest 

Leg Rest Device

 Remove the left and right armrests from

the armrest box. Hold each side of an 
armrest and take it out slowly, one piece at 
a time. 

Please note:

 The armrest is placed

upside down in the box. Place the armrest 
box on a table or on level ground (be
careful to avoid scratching either armrest).

          

 

Step 2. How to Assemble the Leg Rest

Axis

 

cover

Hanger

Bolt

Socket

Air nozzle

Axis

Power line plug

Air tube

Lift the legrest to 
insert the axis into 
the hanger. 

Put down the axis 
cover and screw
on the bolt.

Air hoses connect to the air nozzle
and power cord connects to the 
socket.

Air tube

Massage Chair 
Main Body

OK

3D

-

3D

+

Air 

Intensity

        

Hot 

Rocks

On

/

Off

Auto

Menu

Zero

Set function by pressing Menu key.

Speed

Width

Intensity

3D

20 

min

 Remove the leg rest device from the leg

rest box. Hold the leg rest by both sides to

take it out. Place it on level ground. 

Again, remove carefully to avoid scratches.

          

 

Step 2: How to Use the Remote Control

Take out the remote control and plug it into the socket on the right side of massage chair seat.
When plugging in the remote, be sure to use the alignment guide on the plug and screw the nut
tightly. After attaching the armrest and remote control pocket, place the remote in the pocket.

Plug in the remote 
control and screw 
the nut tightly.

Remote Control

Remote 
Control Plug

Remote Control 
Cord Socket

Pay attention 
to the alignment
guide.

OK

3D

-

3D

+

Air 

Intensity

        

Hot 

Rocks

On

/

Off

Auto

Menu

Zero

Set function by pressing Menu key.

Speed

Width

Intensity

3D

20 

min

Summary of Contents for Presidential

Page 1: ...Please read SAFETY INSTRUCTIONS carefully before using the chair User s Manual Presidential Massage Chair ...

Page 2: ...vitality 11 The armrests are also equipped with pulsating air pressure massage functions to promote blood circulation and total relaxation through your fingertips 12 The waist and hip areas also include multiple air bags to assist with spinal correction and loosen muscular tension in the lumbar region 13 With Chinese medicinal heating on the waist the Presidential promotes blood circulation to rel...

Page 3: ... the chair into a suitable and properly grounded outlet only Make sure the plug is completely inserted into the outlet to reduce risk of short circuit or fire When not in use stop all massage functions turn all controls to the OFF position and unplug Ensure there are no obstacles under behind or in front of the chair when reclining extending or retracting it During operation if at any point you ex...

Page 4: ...back rest arm rest or leg rest Don t stand on the chair during operation Don t move the chair during operation Don t pull out the plug or turn off the power during operation Don t put extremities between or beneath the leg rest Don t use the massage chair while wearing hair ornaments Empty pockets before every massage Don t sit or press on the backrest when the chair is in the reclined position Do...

Page 5: ...r Back Air Bag Arm Air Bag Side Seat Air Bag Calf Air Bag Foot Air Bag Foot Roller Preparation 靠背 Fuse holder Power Cord Socket Power Switch Power Case Backrest Remote Control Pocket Right Shoulder Air Bag Massager Seat Back Seat Cushion Right Armrest Legrest Footrest LED light Left Shoulder Air Bag Massager Left Armrest Base Head Cushion Right Speaker USB Port Lumbar Heat LED Light ...

Page 6: ...actuator Legrest and footrest assembly Left armrest convert frame assembly Shoulder device assembly RK08 massage machine Back cover assembly B Backrest assembly Mechanical Components Diagram NO Q ty Name Mechanical Components List Explosion Diagram Preparation Preparation Mechanical Components List Q ty Name NO Right armrest assembly Right side fender Left side fender Left amrest assembly Power ca...

Page 7: ...t Device Remove the left and right armrests from the armrest box Hold each side of an armrest and take it out slowly one piece at a time Please note The armrest is placed upside down in the box Place the armrest box on a table or on level ground be careful to avoid scratching either armrest Step 2 How to Assemble the Leg Rest Axis cover Hanger Bolt Socket Air nozzle Axis Power line plug Air tube L...

Page 8: ...the rubber cap inside the armrest and loosen the screw inside the hole Tilt the armrest a little upwards and disconnect the air tubes and power cord Continue to tilt the armrest upwards to dismantle it Re insert the rubber plug into the round holes inside the armrest Power Box Socket Chair s Initial State Installation Installation 3 Installation 4 Installation Installation Installation Step 3 How ...

Page 9: ...cts 2 Confirm there is sufficient space for the chair to fully extend Chair Operation Recommendations Adjustment Before Massage Safely Moving Your Massage Chair Adjusting the ChairBeforeYourMassage Caution Do not move the chair during operation in case of accidents or damage Chair Operation How to Move Your Chair Bind the cables and put them on the seat to avoid damage while moving the chair Do no...

Page 10: ...tting 3 In the ON status press this key to adjust the air intensity either in auto mode or in the air massage program 3D 3D 3D 3D Air Intensity Hot Rocks On Off Auto Menu Zero Set function by pressing Menu key Speed Width Intensity 3D 20 min Manual Control Manual Control Up Down Right Leg Rest Up Backrest Down On Off Auto Confirm Button Leg Rest Down Zero Gravity Menu Manual Control Chair Operatio...

Page 11: ...elief Stretch Music Sync Renew Calming Special Select by the navigation keys Auto Manual Airbag Roller Heating Timer Settings Stop Refresh Energy Revive Active Relax Healing Menu Press the Menu button in the main interface to switch to the Menu interface Here you can set all massage functions Press the Menu button in the Menu interface to exit and return to the Main interface Mode Position Width S...

Page 12: ...power switch on the bottom of the back of chair after the rollers return to the storage position Unplug the power cord from the outlet 1 Before using lift the pillow back cushion etc to check if the PU material is broken If there is damage please stop using unplug the chair and contact our tech support for repair 2 Only plug into a grounded outlet Warning Attention 1 Before sitting down make sure ...

Page 13: ...ricity from the outlet Attention Hold the plug properly and pull as illustrated below Do not pull by the cord Clean the chair if necessary Attention After using press ON OFF to end all massage functions and wait for the chair to return to its original position Turn off the power and unplug the chair from the outlet Keep the chair away from moisture dirt and old insulation to prevent damage Restora...

Page 14: ...massage chair to rest for at least half an hour before next use Re connect the electricity to power The plug is not properly inserted into the electrical outlet This is the sound of the air pump motor and mechanical parts Normal wear and tear on inner parts after much use The massage chair suddenly becomes much louder during operation Remove the obstacles turn off the power and allow the massage c...

Page 15: ...del Input voltage Safety design AC120V 60Hz AC220V 50 60Hz AC240V 50Hz Class NW GW Packing size Power Main body 253 302 lbs Armrest 32 43 lbs Legrest footrest 66 76 lbs Main body 59 8 31 38 Armrest 38 5 15 5 28 Legrest footrest 23 20 24 L W H Presidential ...

Reviews: