Corrective Measures
•
Check the Main Shaft Encoder cable and
make sure it is plugged in and undamaged
at connector J42 on the main control board.
•
If the LED toggles at the wrong time, the needle up and down positions will be incorrect. Adjust
the main shaft encoder disc. (See
To adjust the main shaft encoder
disc in the
Main Shaft Encoder
section of this manual.)
•
Check for damage to the main shaft encoder (the black forked sensor shown above) that may
have been caused due to misalignment of the encoder disc causing the disk to collide with the
sensor. Replace the sensor and/or adjust the disc as needed. (See the
Main Shaft Encoder Sensor
section of this manual.
7.
Thread Break Sensor LED (TEST 2)
Normal Operation
•
This LED should flash ON when the check spring in the thread tensioner passes the green thread
break sensor.