102 |
www.HandiQuilter.com
Faulty Operation Symptoms
•
LED is constantly ON or OFF, but does not
trigger when the check spring passes the
sensor.
•
The Thread Break Sensor alarm is being
triggered when the thread is NOT broken.
Corrective Measures
•
Adjust the thread break sensor. (See
To
adjust the thread break sensor
in the
Thread
Break Sensor
section of this manual.)
•
If adjustment of the sensor does not resolve
the problem, it may be necessary to replace
the sensor. (See
To replace the thread break
sensor
in the
Thread Break Sensor
section of
this manual.)
8.
Heartbeat LED
This LED is an indicator that the main processor
on the control board is functioning properly.
Normal Operation
•
The LED flashes in a heartbeat fashion when the control board has been powered up.
Faulty Operation Symptoms
•
The LED is either on solid or off when the board is powered up.
LED flashes at this point
LED is off