Corrective Measures
•
Re-boot the Infinity machine.
•
Upon re-boot, if it still is not flashing
properly, power down the Infinity and
disconnect all cables except the two
power cables connecting to the main
control board. If the Heartbeat LED begins
functioning upon power-up, then one of the
peripherals plugged into the control board is
likely causing the failure. Turn the power off
and plug one cable in at a time, powering
back up between each cable to determine
which cable is causing the fault. Be sure
to wait until all the LEDs go off before
disconnecting any cables! Inspect the cable
and device connected to that cable and
repair or replace it as needed.
9.
TEST 3 LED
This LED is currently not used.
10.
3.3 Volt Supply LED
11.
5 Volt Control Board Supply LED
12.
5 Volt Motor Driver Supply LED
LEDs 10, 11 and 12 indicate various voltage
levels that are being generated on the main
control board. If any of these LEDs are not on,
there will likely be some other type of failure
on the Infinity. Troubleshoot any issues with
these LEDs the same as the Heartbeat LED
(#8). Follow those instructions to determine if
anything connected to the main control board
may be causing a short circuit resulting in the
failure of one of these three power supplies.
Two power cables