116 |
www.HandiQuilter.com
5.
While holding the screw protruding from the laser post, twist the post or slide it in or out as needed
until the laser dot is aligned with where the needle pierces the quilt.
To remove the needle laser
1.
Remove the front plastic panels. (See
To remove the front plastic panels
in section 22,
Front Plastic Panels
.)
2.
Disconnect the 2-pin laser connector from the
front distribution board. Be especially careful
as it is a very tight connector and the wires
can be easily damaged. With this connector it
may be easiest to use a pair of pliers to pull the
connector out of the housing.
3.
Remove the two cable clamps shown with a #1
Phillips screwdriver.