HQ Infinity Service Manual
| 127
2.
Place the sensor mounting screws with washers
from the previous sensor into the mounting holes of
the new sensor.
3.
While holding the sensor with long needle nose
pliers, gently guide the cable through the casting
by pulling on the other end of the guide wire. Make
sure the connector goes down through the plastic
standoff piece and then down through the hole in
the bottom of the upper extrusion.
4. Gently push the main shaft to one side or the other
as you guide the new sensor down in position on
top of the encoder standoff. The two screws should
go through the outer holes in the plastic standoff
and down into the upper extrusion. You should be
pulling the end of the guide wire at the same time
to pull the encoder cable back through the proper
cable path into the region of the main control
board.