140 |
www.HandiQuilter.com
The Infinity will not turn off from the front
switch.
Corrective Measure(s)
The front switch cable is disconnected or
damaged.
•
Check to be sure the front switch cable is plugged into
the top of the control board as well as the top of the
power supply.
Be sure the large connector on the main control board
is fully plugged in at the main control board and up at
the front distribution board.
Binding and/or squeaking wheels
Corrective Measure(s)
Wheel base not adjusted to carriage
•
Loosen wheel hubs (and coupler for rear axle) and
adjust to proper width. Retighten.
Communication error (red icon at top left of
display)
Corrective Measure(s)
USB cable unplugged or in wrong USB port.
•
The rear display USB cable should be plugged into the
top USB port. The front plugs into the back-facing USB
port. Power off and reboot if necessary.
Noise from reciprocating counter weight
piston.
Corrective Measure(s)
Worn or dry.
•
Add proper lubricant to the counterweight piston. For
more information, see
Section 2, HQ Lubrication
Specifications
. Replace the sleeve if there is too much
piston movement in the sleeve.
Camera screen blank on rear display.
Corrective Measure(s)
Camera not properly initialized on rear
display.
•