44 |
www.HandiQuilter.com
10. Reciprocating Counterweight Timing
To check reciprocating counterweight timing
•
When the needle bar is at its lowest position (
bottom dead center
), the reciprocating counter weight
should be at its top position (
top dead center)
.
NOTE
: These two forces counter-oppose each other for optimum balance through-out the
machine’s entire speed spectrum to resolve vibration issues.
To correct reciprocating counterweight timing
1.
Raise the needle bar to its highest position
(
top dead center
), or to where one of the two
counterweight set screws is accessible.
2.
Use a 2.5mm hex tool to loosen the set screw
on the counterweight crank.
NOTE
: Ensure you loosen the larger screw
with a 2.5mm tool and not the smaller drive
pin set screw with a 2mm tool.)