56 |
www.HandiQuilter.com
To check loop lift and hook-to-needle distance timing
1.
Use a 2.5mm hex tool to remove the hopping foot and needle.
2.
Use a #3 flat screwdriver to remove the two needle plate screws. Carefully remove the needle plate
and tip it over onto the hook frame, taking note of which way you twist the wires so you can untwist
them when you replace the needle plate.
Â
IMPORTANT
: Do not twist or pull out the wires so they will get caught in the rotating hook when
the needle plate is reinstalled. The wires must be tight up into the wire channel in the casting and
away from the hook as much as possible to have minimal exposure to the hook.
3.
Use a #1 Phillips screwdriver to remove the
bottom hook guard.
4. Insert a new 100/16 MR needle.