HQ Infinity Service Manual
| 67
To check needle bar height (with hook installed)
•
The needle bar height is set so that when the
hook point passes behind the needle to be
flush with the far right edge of the needle, the
bottom of the hook point is 1.0mm above the
top of the needle eye as shown.
To correct needle bar height (with hook installed)
Â
IMPORTANT
: Before making this adjustment, ensure that the needle is straight. Use a size 16/100
needle.
1.
Install the needle correctly, with the long groove oriented straight out to the front and the needle
pushed all the way up to the stop/sight hole in the needle bar clamp.
NOTE
: Make this adjustment after the loop lift has been first set correctly.
NOTE
: The needle bar height rarely will slip or change. If it is off, it was changed or improperly set
by a technician. Before you change needle bar height, make sure that the adjustment is necessary
and that something else is not wrong (such as a bent needle, poor needle positon, or loop lift
settings) making it look like needle bar height is incorrect.
2. Locate the access hole in the front right cover
for the needle height adjustment.
3.
Lower the needle bar to the lowest position (BDC).
1.0mm