background image

40

41

SETTINGS MENU > UNITS OF MEASURE    

Select the units of 

measure

1.  In the settings 

submenu, rotate the 

Control Turret

 to 

select the units of 

measure   menu 

item. 

2.  Short press the 

Control Turret

 to 

enter the units of 

measure submenu.

3.  Rotate the 

Control Turret

 to move through the options, meters 

and yards. Meters are selected by default.

4.  The selected units of measure (

m

 or 

y

) will display, along with the 

selected zero profile and distance, in the status bar.

5.  Short press the 

Control Turret

 to confirm the selection and return 

to the settings submenu.

SETTINGS MENU > STATUS AUTO HIDING    

Turn auto hiding 

on

 

/

 

off

This function enables 

automatic hiding of all 

interface information, 

aside from the reticle, for 

unobstructed image-view. 

When auto-hide is turned 

on, after 8 seconds of 

inactivity the status bar, 

digital compass, and all 

interface icons will be 

automatically hidden. Shortcut buttons and the menu are disabled 

until the entire interface is again displayed. Press any button to show 

all interface information again. 

NOTE:  When auto-hide is on, the main menu, when open, will 

hide after 15 seconds of inactivity and the rest of the BOLT TD50L 

interface will hide after an additional 8 seconds.

1.  In the settings submenu, rotate the 

Control Turret

 to select the 

status auto hiding   menu item. 

2.  Short press the 

Control Turret

 to enter the auto hiding submenu.

3.  Rotate the 

Control Turret

 to move through the options, on and 

off. Auto hiding is off by default.

4.  Short press the 

Control Turret

 to confirm the selection and return 

to the settings submenu.

SETTINGS MENU > FACTORY RESET    

Reset to factory 

settings

1.  In the settings 

submenu, rotate 

the 

Control Turret

 

to select the factory 

reset   menu item. 

2.  Short press the 

Control Turret

 to 

enter the factory 

reset submenu. Two 

options, Yes and No, 

appear; Yes will restore factory settings and No will cancel the 

operation. Yes is selected by default.

3.  Short press the 

Control Turret

 to select 

Yes

 to confirm the 

factory reset. Factory settings will be restored and the BOLT 

TD50L will reboot automatically; 

OR

 

4.  Rotate the 

Control Turret

 to 

No

 and short press the 

Control 

Turret

 to cancel the factory reset and return to the submenu. 

NOTES:  

•  A factory reset cannot be undone. 
•  The settings listed below will be reset to the factory defaults: 

•  Imaging mode:  Day
•  Display Brightness:  3
•  Magnification:  4×
•  Reticle Type:  1
•  Reticle Color:  Black
•  Zeroing:  A50m (A55y)
•  Wi-Fi:  Off
•  Standby:  Off

•  Date:  2020:01:01
•  Time:  00:00
•  Language:  English
•  Status Auto Hiding:  Off
•  Wi-Fi SSID:   

   BOLT_XXXXXX

•  Wi-Fi Password:  

12345678

SETTINGS MENU > INFO    

Show device 

information

1.  In the settings 

submenu, rotate the 

Control Turret

 to 

move through the 

submenu and select 

the info   menu 

item. 

Summary of Contents for BOLT DIGITAL Series

Page 1: ...I N F I R A Y O U T D O O R BOLT DIGITAL SERIES Bolt Action Optimized Digital Night Vision Scope User s Manual Outdoor...

Page 2: ...the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the d...

Page 3: ...i Fi module for external connectivity to App Picture in Picture PIP Extended eye relief User friendly interface 3 TECH SPECS BOLT TD50L SERIES TD50L SENSOR Resolution 1440 1080 Pixel Size 4 m Frame Ra...

Page 4: ...AC18 BOLT Standard Scope Mount Rings IRAY AC37 BOLT 18650 Battery Extender IRAY AC70 BOLT Digital Series Infrared Illuminator IRAY AC71 Standard Rubber Eyeguard for BOLT IRAY AC74 Objective Lens Cap...

Page 5: ...ort Press Long Press Home screen Adjust the screen brightness Enter exit the stadiametric rangefinder Photo Button Current Screen Menu Short Press Long Press Home screen Take a photo Start stop record...

Page 6: ...s and hold the Brightness and Palette Buttons at the same time for 15 seconds to activate the reticle 2 Short press the Control Turret to enter the quick menu see Using the Quick Menu on page 21 a Sel...

Page 7: ...battery b See Battery Status Icons on page 12 for additional battery information WARNING Never charge the battery pack with a USB adapter that is greater than 5V 2A NOTES You may charge and operate B...

Page 8: ...included are compatible with the BOLT TD50L Using with the Optional Auxiliary Battery When both the built in battery pack and the auxiliary battery are fully charged the BOLT TD50L will select the aux...

Page 9: ...y turning it counterclockwise 2 Connect the smaller USB C end of the data cable to the USB C port 9 3 Connect the standard USB end of the data cable to the external power supply The BOLT TD50L will au...

Page 10: ...ses concentrated infrared light which while not visible to the human eye can cause permanent physical damage 17 OPERATING INSTRUCTIONS Control Features The BOLT TD50L is operated via four control butt...

Page 11: ...icle appear sharp and in focus No additional diopter adjustments are required unless the user wishes to make changes NOTES After this initial adjustment there is no need to rotate the eyepiece adjustm...

Page 12: ...on the operating status of the BOLT TD50L Series 1 2 3 4 5 6 7 8 9 1 Imaging Mode Shows the set imaging mode day moon star Day is the default 2 Zeroing Profile Distance Shows the selected zero profile...

Page 13: ...he desired zero distance 2 Confirm that the rifle is empty safe and pointed in a safe direction with no ammunition near the weapon 3 Adjust the image and device settings following the steps in the Qui...

Page 14: ...Recorded photos are saved to the internal memory card in jpg format videos are saved in mp4 format a Photos are saved in IMG_HHMMSS_XXX jpg format b Videos are saved in VID_HHMMSS_XXX mp4 format c HH...

Page 15: ...3 Enter the Wi Fi password The default password is 12345678 4 Press the Join button When Wi Fi is successfully connected the user may manipulate the BOLT TD50L via the InfiRay Outdoor App See Using th...

Page 16: ...app are saved to the mobile device instead of the internal storage of the BOLT TD50L Once connected you can access files saved to the mobile device In the App press the ViewFinder icon at the bottom...

Page 17: ...xpand the space between the lines b Rotate counterclockwise to shrink the space between the lines 2 As you adjust the space between the horizontal lines the rangefinder values on the right side of the...

Page 18: ...C with distance selected See the Zero Distance Submenu and Reticle Zeroing on the next page for instructions on customizing the nine zero distances 1 Long press the Control Turret to enter the main m...

Page 19: ...sition 5 White Dot Indicates center of initial reticle position NOTE The red X indicates the point of impact It is shown in the figure for illustration purposes and is not an interface element To zero...

Page 20: ...e two triangle icons will indicate the selected digit 5 Long press the Control Turret to save the custom zero distance and return to the Zero Distance submenu 6 The new zero distance appears in the st...

Page 21: ...ss the Control Turret to switch between digits The two triangle icons indicate the selected digit 5 Long press the Control Turret to save the date and return to the home screen SETTINGS MENU TIME Set...

Page 22: ...ol Turret to select the status auto hiding menu item 2 Short press the Control Turret to enter the auto hiding submenu 3 Rotate the Control Turret to move through the options on and off Auto hiding is...

Page 23: ...ing your published warranty period iRayUSA will repair or replace at its discretion any optic that becomes defective during normal use Additionally if we cannot fix your optic in less than one week we...

Page 24: ...microfiber lens cloth There is condensation on the interior or exterior optical surfaces of the lens Wipe the outside optical surfaces with the included microfiber lens cloth Allow the BOLT TD50L to...

Page 25: ...ubject to change without notice For the most up to date specs go to irayusa com Not responsible for typographical errors Ver 1 1080122 800 Railhead Road 316 Fort Worth TX 76106 800 769 7125 682 499 00...

Reviews: