Clip T
Series
Thermal Imaging Attachment
Operating Manual
1.Description
Clip T Series is one of the most compact and cheapest thermal
imager attachment for sights on the market, which is mainly used with
day riflescope and low cost, low power consumption and miniaturization.
2. Components
1.
Objective Lens
2.
Power (P) Button
3.
Type-C Interface
4.
Menu (M) Button
5.
Battery Compartment
6.
Eyepiece Locking Ring
7.
Eyepiece Interface
3. Features
l
12µm thermal imaging detector
l
High image quality
l
The most compact size
l
Ultra light weight
l
Low power consumption and long endurance
l
HD resolution OLED Display
l
IP67 Rating
4. Battery Installation
l
Remove the battery cap by unscrewing it counter clockwise
l
Insert a CR123 with positive pole inwards
l
Return battery cap into housing, screw clockwise until tight
Tips:
Ø
Avoid removing the O shape seal ring.
Ø
Notice the poles of battery placed in right directions.
2
3
1
4
6
7
5
White
hot
Black
hot
Red
hot
Color
Display
lightness
Manual
Calibration
Automatic
Calibration
USB
mode
Battery
Indicator
A
M
6. Menu/Status Bar Icons
7. Operations
7.1 Switch On/Off
Press and hold the
P button(2)
to turn on the device. Waiting for 3
seconds to enter the home interface.
Press and hold the
P button (2)
until the shutdown countdown is 0,
release the button to turn off the device.
7.2 Standby Mode
Press and hold
P button(2)
until the countdown appears, release the
button within 3s countdown to active the standby mode.
Short press
P button(2)
again to exit standby mode.
7.3 Status Bar
In the home interface, there are system information hints at the bottom of
the screen including: Palette, Screen Brightness, Calibration mode,
Battery status etc.
5
.
Mounting Clip T on a Daylight
Scope
Before installing Clip T onto your daylight device, the following
preparations should be made:
l
Select an
adaptor fixture (9)
with an insert of the required diameter
depending on the outer diameter size of the objective lens of your
daylight device.
l
Prepare a
thread adapter insert (8)
that can match with the thread
interface of Clip T eyepiece and metal adaptor fixture.
Insallation
l
Install the
threaded adapter insert (8)
to Clip T by rotating clockwise
along the thread.
l
Rotate the
eyepiece locking ring (6)
counterclockwise to lock the
adapter insert (8)
.
l
Install the
threaded insert (8)
fully into the
adapter fixture (9)
.
l
Install fully the
adapter fixture (9)
with Clip T onto the
objective lens
(10)
of your daylight device.
l
Pull the
handle (11)
on the
adapter
fixture (9)
to lock it firmly on your
daylight device. Check that the
adapter
fixture (9)
is snugly fitted onto
the
objective lens (10)
.
l
If there is space or if the lever cannot reach the locking position, adjust
the locking screw with the hex-nut wrench to ensure that the adapter
fits tightly the objective lens.
Tips:
Ø
Clip may be installed in wrong position while tighten on screw thread,
change its position by adjust eyepiece locking ring.
Ø
The eyepiece interface thread (7) of Clip T series is M30*1.0;
Ø
A thread adapter ring with M52*0.75 thread interface will be presented
in the package of Clip T;
8
9
10
7
11