V1.0.1 - 8 -
Yantai IRay Technology Co., Ltd.
11th Guiyang Street, YEDA
Yantai 264006, P. R. China
3.4 Site Layout Solution
1
)
Reference layout
Refer to Figure 3.7 for the layout plan in a wide space area. The external reference
blackbody is placed directly in front of the infrared camera and made it observable
in the imaging field of view. Pedestrians need to be guided and make sure all of
them can be observed with the thermal imaging camera.
Figure3.7
Arrangement of Thermal Imaging Camera
⚫
Installation direction and height of camera
The installation height and distance of infrared measurement thermal imaging camera
and external reference blackbody are determined according to the specific application
scene and specific model, but the following principles should be followed:
A) The height of the thermal imaging camera should be set so as to be able to take
horizontal pictures of the face of the target (person) and facilitate the operator's
operation; The height of the reference blackbody is set so as not to be blocked by the
target (person);
B) The installation distance between the infrared thermal imaging camera and the
external reference blackbody shall be limited to the range of temperature
measurement;
C) The size of the blackbody in the actual imaging should not be less than 10 pixels.