V1.0.1 - 12 -
Yantai IRay Technology Co., Ltd.
11th Guiyang Street, YEDA
Yantai 264006, P. R. China
Figure4.2
Web Server Login UI
Detailed steps:
1
)
Run Explorer (recommend IE11).
2
)
, as
, to the
Address bar of Explorer. And the login UI as above image.
3
)
Input the right ID and PW (default ID & PW is admin/admin).
4
)
Click Login button to access Server, or else it will warning login error.
5
Troubles Shooting
Troubles Shooting
Fault description
Possible Causes
Method of exclusion
Boot failure
Power connector is loose.
Check whether the power interface is
connected reliably.
Web server could not
access
The network IP address is set
incorrectly
Modify the computer's fixed IP address to the
correct network segment
Low
measuring
accuracy
The thermal camera stabilization
time is too short
Keep the camera stable for more than 40
minutes
Reference blackbody position
setting is incorrect
Reset the position of blackbody