TianXuan M Series Handheld Thermal Camera User Manual 

  

                                                    

                                       

V1.0.0 

                                           

 

 

thermal camera to the object. If the preset registration parameters cannot meet 

the  requirements,  you  can  also  manually  perform  fusion  registration  in  the 

settings. 

4.8.2 Setting Steps 

In the observation interface, press OK shortly to enter the main menu, and select 

"image mode" through the navigation button. Then press OK again to enter the 

secondary menu, there different image mode can be selected by shifting  left or 

right on the navigation button. Save your option by pressing enter button. 

 In the observation interface, click any place on the screen to enter the main menu. 

Click  "image  mode"  and  select  the  desired  image  mode,  and  then  click  on  the 

screen area. The option is saved. 

4.9 Non-uniformity Correction

 

4.9.1 Non-uniformity Correction Introduction 

Non-uniformity correction is used to compensate for non-uniformity of detector 

pixels  or  non-uniformity  caused  by  other  optical  interference.  When  there  are 

more noise in the image, non-uniformity correction is needed, which is common 

when the ambient temperature changes rapidly.

 

4.9.2 Non-uniformity Correction Operations

 

In the imaging interface, press the back button or the gallery button continuously 

to perform non-uniformity correction. 

4.10 Contrast Adjustment

 

In the observation interface, the contrast of the infrared image can by adjusted by 

sliding up and down the arrow button on the "temperature range " on the right 

side of the screen. 

Press "A" in the upper right corner of the interface to return to auto-contrast mode. 

4.11 Other Settings 

Other settings include date and time, unit, language and other items.  

Summary of Contents for TianXuan M Series

Page 1: ...TianXuan M Series Handheld Thermal Camera User Manual V1 0 0 Yantai IRay Technology Co Ltd www iraytek com...

Page 2: ...btained patent rights Anyone shall not dismantle modify crack decompile or make other changes to the terminal equipment without authorization or through any third party The users should bear the relev...

Page 3: ...uct Introduction 2 3 1 Camera View from the front 2 3 2 Buttons View from the rear 3 3 3 Connector and Memory Card 4 3 4 User Interface 4 4 Operation Instruction 5 4 1 Charging 5 4 1 1 Charge with a P...

Page 4: ...rast Adjustment 9 4 11 Other Settings 9 4 11 1 Date and Time 10 4 11 2 Languages 10 4 11 3 Units of Measurement 10 4 11 4 Temperature Gear 10 4 11 5 High Low Temperature Alarm 10 4 11 6 Display Bright...

Page 5: ...s manual is applicable for all products in a range which means that parts of the manual may not apply to a particular model 2 Quick Start Guide 2 1 Steps to Start Please follow the below steps to star...

Page 6: ...of the same name with suffixes of jpg and irg together with the data The file with the suffix irg contains data related to temperature If lost normal analysis cannot be carried out 6 Analysis by APP D...

Page 7: ...allery Long press to perform image uniformity correction 3 Navigation button Make selections for the menu settings gallery by clicking up down left right 4 Power Laser button Long press to turn on off...

Page 8: ...ion of Connector and Memory Card 1 USB Interface Connect a USB cable with the power adapter for charging Connect a USB cable to a computer to charge or transfer data 2 SD Card Standard MicroSD card st...

Page 9: ...ery capacity is displayed 7 Temperature range the temperature range in the current screen can be displayed 4 Operation Instruction 4 1 Charging 4 1 1 Charge with a Power Adapter 1 Plug the power adapt...

Page 10: ...other buttons on the screen or use the navigation button OK to make recording annotation scan the QR code to name the file or cancel saving photos 4 4 View Photos Videos The pictures you took are sav...

Page 11: ...ght and press the enter button to parameterize After setting press OK again to save your option In the observation interface click anywhere on the screen to enter the main menu Click Parameter Setting...

Page 12: ...o compensate the result 4 7 Palettes In the observation interface short press OK to enter the main menu and select palette setting with the navigation button Press OK again to enter the sub menu selec...

Page 13: ...area The option is saved 4 9 Non uniformity Correction 4 9 1 Non uniformity Correction Introduction Non uniformity correction is used to compensate for non uniformity of detector pixels or non unifor...

Page 14: ...if the temperature of more than 15 of the spots in the field of view exceeds 140 it will automatically switch to the 0 550 gear If the temperature of more than 95 of the spots in the field of view is...

Page 15: ...4 11 8 System Settings Device information click to check model version SD card capacity and SD card remaining capacity Restore factory settings click and then press OK to restore the settings to the f...

Page 16: ...function can be used to adjust the position of the picture in picture First select coarse tuning and fine tuning and then adjust the position of the picture in picture by the touch screen or navigati...

Page 17: ...If there is any problem please contact our company for professional maintenance 7 Support and Service 7 1 Technical Supports System training can be carried out for users technical staff and operators...

Page 18: ...n be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increa...

Reviews: