M a i n t e n a n c e
In the event of heater failure please contact the supplier in the first instance. For spare parts or advice, please contact the
supplier or the manufacturer.
Disconnect from the mains before commencing any maintenance procedure including cleaning.
To ensure optimum heat effectiveness, it is recommended that after the heater has been used.
approximately 40-80 hours, the front glass is opened and both the front glass and the reflector are wiped with lint-free
cloth before resealing.
If at any time, a white deposit is seen on the inside of the glass or on the reflector, either or both should be
cleaned with a lint-free cloth.
The heater is supplied with toughened safety glass. In the unlikely event that this should become cracked, please
contact the manufacturer for an immediate replacement.
R e p l a c i n g t h e e m i t t e r
1.
Disconnect the power supply and ensure that the emitter is not
illuminated and that the heater body and emitter are cool.
2.
Unscrew the 4 black screws from the front of the casing. See Fig 6.
3.
Open the front cover. See Fig 7.
4.
Remove the emitter from the spring loaded holders by pushing one
end further into its holder and by pulling the end that is free towards
you, as shown in Fig 8.
5.
Refit in reverse order.
6.
For replacement emitter, please contact the supplier.
Caution: Do not handle the emitter with bare hands. Remove finger marks
with a lint-free cloth and methylated spirits or alcohol. Finger marks will
burn into the quartz emitter causing premature emitter failure.