background image

INFOSEC UPS SYSTEM - 4, rue de la Rigotière - 44700 Orvault - FRANCE -  www.infosec-ups.com 

Hot Line 

– Tel + 33 (0)2 40 76 15 82 - Fax + 33 (0)2 40 94 29 51 - hotline@infosec.fr – 08 11 AA 59 203 12 

7 .   I N S T A L L A T I O N   A N D   O P E R A T I O N  

 

1. Checking 

When  you  receive  your  equipment,  open  the  packaging  and  check  that  your  AVR  has  not 
been damaged. Packaging includes: 

R1 600/1200/2000 VA 

: AVR unit and a user guide. 

 
 

2. Placement & storage conditions 

The  AVR  has  been  designed  to  operate  in  a  protected  environment,  at  temperatures 
between  0°C  and  40°C  and  at  a  humidity  level  ranging  between  0%  and  90%  (no 
condensation). 
Do  not  obstruct  the  ventilation  slots.  Install  the  unit  in  an  environment  which  is  free  from 
dust, chemical vapours and conductors. Moreover, in order to avoid any interference, keep 
the AVR at least 20cm away from the CPU (central processing unit). 

 

3.

 

Connection 

Check the identification plate to make sure that the power supply is compatible with network 
voltage and that the device is powerful enough. Plug the AVR into a 2-pole, earthed outlet . 
Then, connect devices to the AVR. 

 

4. On/Off

 

To turn the AVR unit on, press the power switch. To make sure the AVR is ON, check if the 
green led is lightning. If the red led is on, it means that the AVR is regulation the voltage. To 
turn it off, press the power switch again. 

 

 

5. Connect Modem/Phone/Network for surge protection 

Connect a single modem/phone line to a surge protected “IN” outlet on the back panel of the 
UPS unit. Connect the “OUT” outlet to the computer with another phone line cable. 

Caution

:  The  telephone  line  lightning  arrester  could  be  rendered  inoperable  if  improperly 

installed. This surge protection device is for indoor use only. Never install telephone wiring 
during a lightning storm. 

 

 

8 .   T R O U B L E   S H O O T I N G  

 

Should  the  AVR  fail  to  function  correctly  we  recommend  you  perform  the  following  tests 
before calling the Hot Line. 

 

Check list:  

 

Is the main switch in the “ON” position? 

  Is the AVR plugged into the mains power supply? 
  Does the power supply fall within specified unit values? 
  Is the AVR overloaded? 

 

Summary of Contents for R1 1200

Page 1: ...User guide _________________________ 2 Notice d utilisation __________________ 7 600 1200 2000 VA ...

Page 2: ...ut remove the plug from the utility power outlet Install the AVR in a temperature and humidity controlled indoor area free of conductive interference It should not be exposed to direct sunlight or sources of heat Do not cover the ventilation slots Disconnect the AVR from AC power before cleaning with a damp cloth no cleaning products In an emergency situation switch the AVR to the Off position and...

Page 3: ...de an accurate description of the problem with the following details type of equipment powered by the AVR indicator led status installation and environmental conditions You will find the technical information you require on your guarantee or on the identification plate on the back of the unit If convenient you may enter the details in the following box Model Serial number Date of purchase R1 Pleas...

Page 4: ...33 0 2 40 76 15 82 Fax 33 0 2 40 94 29 51 hotline infosec fr 08 11 AA 59 203 12 4 6 D E S C R I P T I O N R 1 6 0 0 1 2 0 0 2 0 0 0 V A Front face 1 Power Switch 2 Boost Buck LED Red LED 3 Power On Off LED Green LED 4 Phone Modem surge protection 5 Output Receptacle 6 Input Cord 7 Circuit Breaker ...

Page 5: ...ompatible with network voltage and that the device is powerful enough Plug the AVR into a 2 pole earthed outlet Then connect devices to the AVR 4 On Off To turn the AVR unit on press the power switch To make sure the AVR is ON check if the green led is lightning If the red led is on it means that the AVR is regulation the voltage To turn it off press the power switch again 5 Connect Modem Phone Ne...

Page 6: ...ets 2 2 2 Tel ADSL protection RJ 11 1 IN 1 OUT RJ 11 1 IN 1 OUT RJ 11 1 IN 1 OUT PHYSICAL CARACTERISTICS Dimensions HxWxD mm 113 x 115 x 192 Weight kg 1 4 1 6 2 INPUT TECHNICAL CARACTERISTICS Voltage 220 VAC Plage de tension Voltage range 184 263 VAC Fréquence frequency 50 Hz or 60 Hz OUTPUT TECHNICAL CARACTERISTICS Automatic voltage regulation 10 Protection Short circuit Overload ENVIRONMENT Idea...

Page 7: ...doit être facilement accessible Pour désactiver complètement l appareil débrancher le câble d alimentation de l appareil de la prise de courant Ne pas installer le régulateur en milieu trop chaud ou trop humide Ne pas l exposer aux rayonnements solaires ou à toute autre source de chaleur Ne pas couvrir les grilles de ventilation Débrancher le régulateur avant de le nettoyer Ne pas utiliser de déte...

Page 8: ...ntes qui vous seront dans tous les cas demandées le modèle du régulateur le numéro de série la date d achat et le type de matériel alimenté par le régulateur ainsi qu une description précise du problème comprenant état des voyants conditions d installations et d environnement Ces renseignements sont notés sur le bon de garantie ou inscrits sur la plaque signalétique à l arrière de l appareil Vous ...

Page 9: ... 15 82 Fax 33 0 2 40 94 29 51 hotline infosec fr 08 11 AA 59 203 12 9 6 D E S C R I P T I O N R 1 6 0 0 1 2 0 0 2 0 0 0 V A Face avant 1 Bouton Power 2 Mode régulateur voyant rouge 3 Indicateur de marche voyant vert 4 Protection Tel ADSL RJ11 5 2 prises Françaises 6 Cordon d alimentation 7 Fusible thermique ...

Page 10: ... la charge Brancher le cordon d alimentations sur une prise de courant secteur puis connecter les charges aux prises de sortie 4 Marche Arrêt Pour mettre en route le régulateur actionner l interrupteur 1 et vérifier que le voyant vert 2 est allumé Le voyant rouge 3 est allumé lorsque le R1 est en mode régulation de tension Pour éteindre le régulateur mettre d interrupteur sur Off 5 Protection télé...

Page 11: ...e Tel ADSL RJ 11 1 IN 1 OUT RJ 11 1 IN 1 OUT RJ 11 1 IN 1 OUT CARACTERISTIQUES PHYSIQUES Dimensions HxLxP mm 113 x 115 x 192 Poids net kg 1 4 1 6 2 CARACTERISTIQUES TECHNIQUES EN ENTREE Tension nominale 220 VAC Plage de tension 184 263 VAC Fréquence 50 Hz or 60 Hz CARACTERISTIQUES TECHNIQUES EN SORTIE Régulation automatique de tension 10 Protection Courts circuits et surcharge INDICATEURS LUMINEUX...

Reviews: