8.   C O M P U T E R   I N T E R F A C E  

 
The interface USB at the back of the UPS may be connected to the computer. This port 
enables the computer to control the UPS status. The main functions are as follows : 

  Transmission of a visual alarm in case of power failure 

  Automatic file closure prior to battery running out 

 UPS 

shutdown 

 

9 .   P R O T E C T I O N   F A X / M O D E M   L I N E  

 
If you wish to protect a fax or a modem, connect the telephone cable from the wall outlet to 
the “IN” jack. Connect the telephone cable (provided) from the “OUT” jack to the fax or 
modem. 

Caution:

 The telephone line current lightning feature could be rendered inoperable if 

improper installed. This surge protection device is for indoor use only and never install 
telephone wiring during a lightning storm. 

Note:

 This connection is optional. It is not necessary to use this UPS. 

 

1 0 .   B A T T E R Y  

 
The battery is the only UPS component which is not in permanent use. It has a product life 
of approximately 3 to 5 years. However, frequent major discharges or exposure to 
temperatures over 20

°

C will shorten its product life. We therefore recommend that users 

recharge the battery once every 3 months when the unit is not in use in order to compensate 
for natural discharging. UPS back-up functioning time will depend on the load powered, the 
age and the condition of the batteries. 
 

WARNING ! 

 

Batteries should always be replaced by qualified technicians. Batteries have a very high 
short circuit current : 

connection errors could cause electric arcs resulting in 

serious burns

 

 

11.  T R O U B L E   S H O O T I N G  

 
Should the UPS fail to function correctly we recommend you to perform the following tests 
before calling the After Sales Department. 
 

Check list :  

 

  Is the main switch in the « ON » position ? 

  Is the UPS plugged into a powered mains ? 

  Does the power supply fall within specified unit values ? 

  Has the fuse gone in the mains plug ? 

  Is the UPS overloaded ? 

  Is the battery low or defective ? 

 
 

Summary of Contents for IPEL EVOLUTION 1000 VA

Page 1: ...User s guide_________________________________2 Notice d utilisation ___________________________9 iPEL evolution 350 500 700 1000 VA...

Page 2: ...phone line surge protection 3 S AF E T Y I N S T R U C T I O N S S e c u r i t y The UPS unit is potentially using hazardous voltages Do not take this equipment apart It does not contain accessible co...

Page 3: ...hould be recharged every 3 months failure to do so it could result in battery damage 5 AF T E R S AL E S S E R V I C E IMPORTANT When calling the After Sales Department please have the following infor...

Page 4: ...A C K P A N E L F U S E R E P L A C E M E N T Replacement fuse AC input socket fuse Protection fuse in this place Insert a screwdriver in the slot to open the slide On Off switch Green led lighting A...

Page 5: ...ntilation grills Install the unit in an environment which is free from dust chemical vapours and conductors Moreover in order to avoid any interference keep the UPS at least 20 cm away from the CPU ce...

Page 6: ...connection is optional It is not necessary to use this UPS 1 0 B AT T E R Y The battery is the only UPS component which is not in permanent use It has a product life of approximately 3 to 5 years Howe...

Page 7: ...arm buzzer beeps continuously when AC supply is normal 1 Overload of the UPS 1 Verify that the load matches the UPS capability specified in the specs 1 Overload of the UPS 1 Remove some non critical l...

Page 8: ...V or 220 230 240 V Voltage range 85 140 V 162 290 V INPUT Frequency 45 65 Hz auto detection Voltage 110 115 120 V or 220 230 240 V Regulation 10 battery mode OUTPUT Frequency Battery mode 50 60 Hz 1...

Page 9: ...st me de r gulation de tension Port de communication USB Fonction conomie d nergie D marrage froid Red marrage automatique lorsque l alimentation est r activ e Faible encombrement faible poids Protect...

Page 10: ...de vie des batteries Les batteries de l onduleur doivent tre recharg es tous les 3 mois en cas de non utilisation 5 S E R V I C E AP R E S V E N T E IMPORTANT Lors d un l appel au Service Apr s Vente...

Page 11: ...F U S I B L E Ici fusible de rechange Prise d alimentation Porte fusibles Fusible de protection en place Ins rer un tournevis plat dans l encoche Tirer pour d gager le porte fusibles Bouton marche arr...

Page 12: ...de contaminants conducteurs Par ailleurs afin d viter toute perturbation lectromagn tique loigner l onduleur d au moins 20 cm de l unit centrale et du moniteur 4 Connexion V rifier sur la plaque signa...

Page 13: ...mal 1 0 B AT T E R I E La batterie est la seule partie occasionnellement utilis e dans l onduleur Sa dur e de vie est de l ordre de 3 5 ans Par contre de fr quentes d charges profondes et une temp rat...

Page 14: ...e la charge branch e correspond la capacit de l onduleur Retirer les l ments de charge non indispensable ex imprimante Arr ter puis red marrer l onduleur 1 L onduleur est surcharg ou l quipement conne...

Page 15: ...age de tension 85 140 V 162 290 V TENSION D ENTREE Fr quence 45 65 Hz auto d tection Tension de sortie 110 115 120 V ou 220 230 240 V Plage de tension 10 mode batterie TENSION DE SORTIE Fr quence Mode...

Reviews: