background image

INFOSEC UPS SYSTEM - 4, rue de la Rigotière – 44700 Orvault – FRANCE -  www.infosec.fr 

Hot Line :   tel : + 33 (0)2 40 76 15 82  -  fax : + 33  (0)2 40 94 29 51  -  hotline@infosec.fr – 05 05 04 205 06

 

1 2 .   T E C H N I C A L   S P E C I F I C A T I O N S  

 

 

 

iPEL e 350 iPEL e 500 iPEL e 700  iPEL e 1000 

Technology 

Line interactive with Auto Voltage Regulation 

Output form 

Modified sine wave 

Protection 

discharge / overcharge and overload protection     

+ fax modem line 

Power 

350 VA 

500 VA 

700 VA 

1000 VA 

TECHNOLOGY 

Power factor 

0,6 0,6 0,6 0,5 

Dimensions 

WxDxH

 

100 X 330 X 140 (mm) 

Weight kg 

4,8 5  6  6,5 

PHYSICAL 

Output connectors 

3 UPS protected outlets / 1 surge protected outlet / 

2 surge protected RJ11 

Voltage 

[110-115-120 V] or [220 - 230 - 240 V] 

Voltage range  

[85 - 140 V] [162 - 290 V] 

INPUT 

Frequency 

45 - 65 Hz auto detection

 

Voltage 

[110-115-120 V] or [220 - 230 - 240 V] 

Regulation 

+ / - 10 % (battery mode) 

OUTPUT 

Frequency  

Battery mode : 50 - 60 Hz +/- 1 Hz 

Type 

Sealed maintenance free 

Backup time 

8 to 30 minutes (depending on the load)

 

BATTERY 

Recharge time 

8 hours to 90 % after a complete discharge 

FILTER Spike 

protection 

125 joules 

Noise level 

< 40 dB at 1 meter 

ENVIRONMENT 

Operating 
environment 

0° C - 40° C, 0 to 90 % humidity rate 

(non condensing) 

AC  Mode 

Green led lighting 

Backup Mode 

Yellow led flashing 

INDICATOR 

Fault 

Red led lighting 

Battery Mode 

Sounding every 10 seconds 

Battery replacement 

Sounding every 2 seconds 

Low battery 

Sounding second until automatic stop 

Overload or defect 

Every 0,5 second 

AUDIBLE          

ALARM 

Fault 

Continuously sounding 

INTERFACE Communication 

port

USB 

MANUFACTURING  Security / Standard 

CE - ISO 9001 - PCT 

 

Summary of Contents for IPEL EVOLUTION 1000 VA

Page 1: ...User s guide_________________________________2 Notice d utilisation ___________________________9 iPEL evolution 350 500 700 1000 VA...

Page 2: ...phone line surge protection 3 S AF E T Y I N S T R U C T I O N S S e c u r i t y The UPS unit is potentially using hazardous voltages Do not take this equipment apart It does not contain accessible co...

Page 3: ...hould be recharged every 3 months failure to do so it could result in battery damage 5 AF T E R S AL E S S E R V I C E IMPORTANT When calling the After Sales Department please have the following infor...

Page 4: ...A C K P A N E L F U S E R E P L A C E M E N T Replacement fuse AC input socket fuse Protection fuse in this place Insert a screwdriver in the slot to open the slide On Off switch Green led lighting A...

Page 5: ...ntilation grills Install the unit in an environment which is free from dust chemical vapours and conductors Moreover in order to avoid any interference keep the UPS at least 20 cm away from the CPU ce...

Page 6: ...connection is optional It is not necessary to use this UPS 1 0 B AT T E R Y The battery is the only UPS component which is not in permanent use It has a product life of approximately 3 to 5 years Howe...

Page 7: ...arm buzzer beeps continuously when AC supply is normal 1 Overload of the UPS 1 Verify that the load matches the UPS capability specified in the specs 1 Overload of the UPS 1 Remove some non critical l...

Page 8: ...V or 220 230 240 V Voltage range 85 140 V 162 290 V INPUT Frequency 45 65 Hz auto detection Voltage 110 115 120 V or 220 230 240 V Regulation 10 battery mode OUTPUT Frequency Battery mode 50 60 Hz 1...

Page 9: ...st me de r gulation de tension Port de communication USB Fonction conomie d nergie D marrage froid Red marrage automatique lorsque l alimentation est r activ e Faible encombrement faible poids Protect...

Page 10: ...de vie des batteries Les batteries de l onduleur doivent tre recharg es tous les 3 mois en cas de non utilisation 5 S E R V I C E AP R E S V E N T E IMPORTANT Lors d un l appel au Service Apr s Vente...

Page 11: ...F U S I B L E Ici fusible de rechange Prise d alimentation Porte fusibles Fusible de protection en place Ins rer un tournevis plat dans l encoche Tirer pour d gager le porte fusibles Bouton marche arr...

Page 12: ...de contaminants conducteurs Par ailleurs afin d viter toute perturbation lectromagn tique loigner l onduleur d au moins 20 cm de l unit centrale et du moniteur 4 Connexion V rifier sur la plaque signa...

Page 13: ...mal 1 0 B AT T E R I E La batterie est la seule partie occasionnellement utilis e dans l onduleur Sa dur e de vie est de l ordre de 3 5 ans Par contre de fr quentes d charges profondes et une temp rat...

Page 14: ...e la charge branch e correspond la capacit de l onduleur Retirer les l ments de charge non indispensable ex imprimante Arr ter puis red marrer l onduleur 1 L onduleur est surcharg ou l quipement conne...

Page 15: ...age de tension 85 140 V 162 290 V TENSION D ENTREE Fr quence 45 65 Hz auto d tection Tension de sortie 110 115 120 V ou 220 230 240 V Plage de tension 10 mode batterie TENSION DE SORTIE Fr quence Mode...

Reviews: