background image

INFOSEC UPS SYSTEM - 4, rue de la Rigotière - 44700 Orvault - FRANCE -  www.infosec-ups.com 

Hot Line – Tel + 33 (0)2 40 76 15 82 - Fax + 33 (0)2 40 94 29 51 - hotline@infosec.fr – 02 16 AA 59 204 23 

7 .   I N S T A L L A T I O N   A N D   O P E R A T I O N  
1. Checking 

NOTE: 

Before the installation of the unit, please inspect it. Be sure that nothing inside the 

package is damaged. Please keep the original package in a safe place for future use. 

Packaging includes: 

1 UPS unit, 1 IEC output cable, 1 Infopower software and 1 user guide. 

2. Charging the batteries

 

This unit is shipped from the factory with its internal battery fully charged, however, some 

charge may be lost during shipping and the battery should be recharged prior to use. Plug the 

unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged-

in, with no load, for at least 8 hours. 

The  UPS will  automatically  recharge  its  own  batteries  whenever  the switch  is  in  the  “ON” 

position. You may use the UPS immediately, however the back-up power capacity may be 

lower than the nominal value required. 

3. Placement & storage conditions 

The UPS has been designed to operate in a protected environment, at temperatures between 

0°C and 40°C and at a humidity level ranging between 0% and 90% (no condensation). 

Do not obstruct the ventilation slots. Install the unit in an environment which is free from dust, 

chemical vapours and conductors. Moreover, in order to avoid any interference, keep the UPS 

at least 20cm away from the CPU (central processing unit). 

4.

 

Connection 

Check the identification plate at the back of the UPS to make sure that the power supply is 

compatible with network voltage and that the device is powerful enough to protect the given 

load. Plug the UPS into a 2-pole, earthed outlet. Then, connect computer-related devices to 

the UPS. 

5. On/Off

 

To turn the UPS unit on, lightly press the power switch. To turn it off, press the power switch 

again. Make sure that the power switch is kept in the “ON” position, otherwise the UPS will be 

disabled and your equipment unprotected in the event of power failure.  

Note

For maintenance purposes, please turn the UPS on before the PC and other loads, and 

turn it off after the connected loads are turned off.

 

6. DC Start 

X4 RM PLUS units are equipped with an integrated DC start function. To start the UPS in the 

absence of a power supply and with a full battery, simply press the button. 

 

8 .   C O M P U T E R   I N T E R F A C E  

 

To prevent an abrupt computer system shutdown, connect a USB cable to your computer. 

Then you can install and use the automatic shutdown software (free download from web site).

 

The USB communication port at the back of the UPS enables the computer to directly control 

UPS status.  

 

The main functions are as follows: 

- Transmission of a visual alarm in event of power failure 

- Automatic file closure prior to the battery going flat 

- Computer & UPS shutdown 

For more information, go to the website: www.infosec-ups.com  

 

 

 

Summary of Contents for X4 RM PLUS 1000

Page 1: ...600 800 1000 2000 3000 VA User guide_____________________ 2 Notice d utilisation _____________ 10 _________________ 19...

Page 2: ...S e c u r i t y IMPORTANT Installing and connecting UPS in a way that does not comply with accepted practices releases Infosec Communication from any liability Risk of electric shock The UPS unit uses...

Page 3: ...clean dirtied clothes Do not throw the battery into a fire It may explode It has to be disposed of separately at the end of its useful life Refer to local legislation and regulations The UPS contains...

Page 4: ...al information you require on your guarantee or on the identification plate on the back of the unit If convenient you may enter the details in the following box Model Serial number Date of purchase X4...

Page 5: ...P T I O N F R O N T P A N E L X 4 R M P L U S 6 0 0 8 0 0 1 k 2 k V A X 4 R M P L U S 3 k V A L C D D I S P L A Y R E A R P A N E L X 4 R M P L U S 6 0 0 8 0 0 V A On Off Switch LCD Screen Input volta...

Page 6: ...40 76 15 82 Fax 33 0 2 40 94 29 51 hotline infosec fr 02 16 AA 59 204 23 6 X 4 R M P L U S 1 k V A X 4 R M P L U S 2 k V A X 4 R M P L U S 3 k V A AC input outlet IEC protected UPS outlets FR SCHUKO...

Page 7: ...al vapours and conductors Moreover in order to avoid any interference keep the UPS at least 20cm away from the CPU central processing unit 4 Connection Check the identification plate at the back of th...

Page 8: ...ng tests before calling the Hot Line Check list Is the main switch in the ON position Is the UPS plugged into the mains power supply Does the power supply fall within specified unit values Has the fus...

Page 9: ...ion 10 Frequency 50 Hz 1 Hz Crest ratio 3 1 BATTERY Battery charger Operates when the UPS is connected to mains Cold start no mains Yes Batteries type number 12V 7AH 1 12V 9AH 1 12V 7AH 2 12V 9AH 2 12...

Page 10: ...Connecteurs RJ45 2 I N S T R U C T I O N S D E S E C U R I T E IMPORTANT Installer et connecter les onduleurs de fa on non conforme aux r gles de l art d sengage Infosec Communication de toute respons...

Page 11: ...able celle ci risquerait d exploser Ne pas ouvrir ni ab mer la batterie L lectrolyte base d acide sulfurique peut tre toxique et nocif pour la peau et les yeux En cas de contact laver abondamment l ea...

Page 12: ...de l alarme conditions d installations et d environnement Ces renseignements sont not s sur le bon de garantie ou inscrits sur la plaque signal tique l arri re de l appareil Vous pouvez galement les r...

Page 13: ...V A N T X 4 R M P L U S 6 0 0 8 0 0 1 k 2 k V A X 4 R M P L U S 3 k V A A F F I C H A G E L C D R E A R P A N E L X 4 R M P L U S 6 0 0 8 0 0 V A Bouton On Off Ecran LCD Tension d entr e Tension de so...

Page 14: ...40 76 15 82 Fax 33 0 2 40 94 29 51 hotline infosec fr 02 16 AA 59 204 23 14 X 4 R M P L U S 1 k V A X 4 R M P L U S 2 k V A X 4 R M P L U S 3 k V A Prise d alimentation Prises IEC avec autonomie Prise...

Page 15: ...temp rature comprise entre 0 C et 40 C et un taux d humidit compris entre 0 et 90 sans condensation Ne pas obstruer les grilles de ventilation Installer l appareil dans un endroit exempt de poussi re...

Page 16: ...e de vie est de l ordre de 3 5 ans Par contre de fr quentes d charges profondes et une temp rature sup rieure 20 C r duisent cette dur e de vie Il est recommand de recharger la batterie tous les 3 mo...

Page 17: ...charg V rifier que la charge branch e correspond la capacit de l onduleur Retirer les l ments de charge non indispensable puis red marrer l onduleur En cas de panne de secteur temps de sauvegarde r du...

Page 18: ...BATTERIE Chargeur batterie Charge automatique d s branchement secteur D marrage froid sect abs oui Type et nombre de batteries 12V 4 5AH 1 12V 7AH 1 12V 7AH 2 12V 9AH 2 12V 7AH 4 Tension de charge 13...

Page 19: ...EM 4 rue de la Rigoti re 44700 Orvault FRANCE www infosec ups com Hot Line Tel 33 0 2 40 76 15 82 Fax 33 0 2 40 94 29 51 hotline infosec fr 02 16 AA 59 204 23 19 1 X4 RM PLUS X4 RM PLUS 19 X4 RM PLUS...

Page 20: ...UPS SYSTEM 4 rue de la Rigoti re 44700 Orvault FRANCE www infosec ups com Hot Line Tel 33 0 2 40 76 15 82 Fax 33 0 2 40 94 29 51 hotline infosec fr 02 16 AA 59 204 23 20 3 5 CEE 7 7 FR SCHUKO 4 24 40...

Page 21: ...INFOSEC UPS SYSTEM 4 rue de la Rigoti re 44700 Orvault FRANCE www infosec ups com Hot Line Tel 33 0 2 40 76 15 82 Fax 33 0 2 40 94 29 51 hotline infosec fr 02 16 AA 59 204 23 21 X4 RM PLUS CE LVD EMC...

Page 22: ...0 Orvault FRANCE www infosec ups com Hot Line Tel 33 0 2 40 76 15 82 Fax 33 0 2 40 94 29 51 hotline infosec fr 02 16 AA 59 204 23 22 6 X 4 R M P L U S 6 0 0 8 0 0 1 k 2 k V A X 4 R M P L U S 3 k V A L...

Page 23: ...00 Orvault FRANCE www infosec ups com Hot Line Tel 33 0 2 40 76 15 82 Fax 33 0 2 40 94 29 51 hotline infosec fr 02 16 AA 59 204 23 23 X 4 R M P L U S 1 k V A X 4 R M P L U S 2 k V A X 4 R M P L U S 3...

Page 24: ...STEM 4 rue de la Rigoti re 44700 Orvault FRANCE www infosec ups com Hot Line Tel 33 0 2 40 76 15 82 Fax 33 0 2 40 94 29 51 hotline infosec fr 02 16 AA 59 204 23 24 7 1 1 1 IEC 2 8 ON 3 40 90 20 CPU 4...

Page 25: ...UPS SYSTEM 4 rue de la Rigoti re 44700 Orvault FRANCE www infosec ups com Hot Line Tel 33 0 2 40 76 15 82 Fax 33 0 2 40 94 29 51 hotline infosec fr 02 16 AA 59 204 23 25 www infosec ups com 9 3 5 20...

Page 26: ...INFOSEC UPS SYSTEM 4 rue de la Rigoti re 44700 Orvault FRANCE www infosec ups com Hot Line Tel 33 0 2 40 76 15 82 Fax 33 0 2 40 94 29 51 hotline infosec fr 02 16 AA 59 204 23 26 6 6...

Page 27: ...type CEE 7 7 2 2 2 2 2 ADSL RJ45 1 1 230 x 438 x 86 300 x 438 x 86 460 x 438 x 86 6 5 7 7 11 3 14 4 23 6 220 VAC 162 268 VAC 50 60 220 VAC AVR 10 50 1 3 1 12V 4 5AH 1 12V 7AH 1 12V 7AH 2 12V 9AH 2 12...

Page 28: ...INFOSEC UPS SYSTEM 4 rue de la Rigoti re 44700 Orvault FRANCE www infosec ups com Hot Line Tel 33 0 2 40 76 15 82 Fax 33 0 2 40 94 29 51 hotline infosec fr 02 16 AA 59 204 23 28...

Reviews: