Storage Temperature: -20 to 60 degrees Celsius (-4 to 140 degrees Fahrenheit); For best results
store between 5 to 20 degrees Celsius (41 to 68 degrees Fahrenheit)
•
Environmental Resistance: Components used are at least NEMA 4x compliant
9.2.
Power
•
Battery LiMNNi 11.1v 4Ah
•
Battery Cycle Life: 80% of initial capacity at 1000 charge cycles
•
Time to charge battery: 3.5 hours
•
Temperature range for charging: 0 to 45 degrees Celsius (32 to 113 degrees Fahrenheit)
•
Number of TX Measurements starting with fully charged battery: approximately 40
•
Number of RX Measurements starting with fully charged battery: greater than 80
9.3.
Operational
•
Recommended Minimum Pipe Segment Length: 20 ft.
•
Recommended Maximum Pipe Segment Length: 800 ft.
•
Recommended Pipe Flow Levels: Typically less than 50%; Measurements in higher flow levels may
also work, but are likely to produce lower pipe assessments.
•
Pipe Diameters: 6” to
12
”; Measurements in larger & smaller diameter pipes may also
work but have
not been explicitly included in the current blockage assessment algorithms.
•
Pipe Material: PVC, HDPE, Ductile Iron, Concrete, Vitrified Clay; and others.