background image

 

4

1. GSM Converter Description.  

The  GSM  converter  provides  a  noiseless  48v  telephone  line,  similar  to  a 
conventional  line  (PSTN),  in  case  there  are  any  problems  or  it  has  been 
sabotaged.  
In  case  the  PSTN  telephone  line  does  not  exist,  any  device  connected  to 
the  GSM  converter  will  be  able  to  establish  a  connection  using  the 
generated GSM phone line.  

 

2. Equipment Installation.  

Note: The power supply must never be connected and switched on before 
the SIM card is inserted and you have connected the Ariel. 
 

 
GSM converter inputs and outputs 

 

Input PSTN <POST2>: Connect your main incoming PSTN line 

here – do not connect any equipment to this connection. 

 

M60  Connection  <POST1>:  Connect  equipment  here  -  the 

equipment  will  use  the  PSTN  line  as  the  default  connection  and 
swap to the GSM network in the case of a failure. 

 

+ 12v Connection: 12vdc at 1AMP 

 

Internal Backup Battery: Already fitted should be changed every 

3 Years. 

 

240VAC:  Please  use  the  supplied  transformer  or  ask  us  for  other 

options. 

  
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 

Summary of Contents for M60

Page 1: ...1 The Packs Infotel GSM Converter V2 Installation Manual V7 ...

Page 2: ...Telephone line input 5 5 2 Telephone line output 6 5 3 Telephone line monitoring 6 5 3 1 Line voltage verification 6 5 3 2 Tone voltage verification 6 5 4 Incoming Calls 6 6 Working without a telephone line 7 6 1 Telephone line outputs 7 6 2 GSM converter line characteristics 7 6 3 Outgoing GSM telephone operation 7 6 4 Restoring of PSTN line 7 7 Function programming 8 8 Specification 9 ...

Page 3: ...240 VAC Power Connection The GSM Converter comes with its own 240 VAC to 12VDC plug in power supply and internal battery back up facility Plug the transformer into your wall socket and the output plug into the rear of the unit Other Power options are available 12 VDC Power Connection If you do not wish to use the supplied 240vac power supply then you need to connect a supply of 12 VDC to the power...

Page 4: ... supply must never be connected and switched on before the SIM card is inserted and you have connected the Ariel GSM converter inputs and outputs Input PSTN POST2 Connect your main incoming PSTN line here do not connect any equipment to this connection M60 Connection POST1 Connect equipment here the equipment will use the PSTN line as the default connection and swap to the GSM network in the case ...

Page 5: ...t 2 If applicable 4 Connect your M60 to the provided cable or the RG11 socket Post 1 5 Connect the 12vdc supply and switch the on off switch to on On initial start up a general equipment reset will be made If the connections were correctly made and there are not any telephone line problems variations in the system should not be noticed except for signal strength 5 Telephone Line Functioning 5 1 Te...

Page 6: ...the line will wait and then it will check the voltage again If after that time the failure continues the unit will move any outgoing calls to the GSM network 5 3 2 Tone voltage verification If the GSM converter checks the tones frequency and the result was not correct it will move any outgoing calls to the GSM network 5 4 Incoming calls The GSM converter will put incoming calls though to the POST ...

Page 7: ...he GSM converter will call the number dialed through its GSM module Call Tones must be DTMF Once the communication has started the GSM converter will link the audio between the equipment and the receiver Any call through the GSM line will finish when the equipment that started the call hangs up The GSM converter will then wait for another call 6 4 Restoring of PSTN line The GSM converter will cont...

Page 8: ... 01 set barring default setting 00 7 1 3 Pin code 1 Start PIN code check and automatic PIN lock function 07 1234 07 command 1234 your current SIM card PIN code If set successfully the device will start the PIN code check and automatically change the current SIM Card into PIN on from PIN off 2 Close PIN code check and automatic PIN lock function 08 1234 08 command 1234 your current SIM card PIN cod...

Page 9: ...Dimension 170mm 118mm 30mm excluding antenna GSM 850 900 1800 1900 Mhz Quad band Power Supply Required 12VDC 1A Backup Battery o Standby 24 Hrs o Talk time 2 Hrs Operating temperature 10c to 60 C Storage Temp 20C to 70 C ...

Reviews: