background image

M2M CONTROL C660  -  Technical Manual V2.00                                                

 

 

www.m2mcontrol.de  
support@m2mcontrol.de 

 

Page 29 of 36 

 

Specification for the 99-channels multi-GNSS receiver 

 

MediaTek MT3333 Single Chip Super Sensitivity 

General: 

99 acquisition / 33 tracking / up to 210 PRN channels. 
Multi GNSS engine for GPS, GLONASS and QZSS 
Support DGPS, SBAS(WAAS,EGNOS,MSAS,GAGAN). 
A-GPS capable. 
Anti-jamming, Multi-tone Active Interface Canceller. 

 

 

 

Update Rate: 

NMEA @ up-to 4 Hz 

 

 

 

 

Accuracy: 

Position 

<2.5m CEP 

 

Velocity 

<0.1m/s 

 

DGPS/SBAS 

<2.5m CEP

1

 

 

 

 

Sensitivity: 

Tracking/navigation 

-165 dBm 

 

Reacquisition 

-160 dBm 

 

Cold Start (Autonomous) 
(GPS chipset reference parameters) 

-148 dBm 

 

 

 

Time-To-First-Fix

2

Autonomous Operation in Standard Sensitivity Mode 

 

Reacquisition

3

 

< 1 sec. 

 

Hot Start

4

 

< 1 sec. 

 

Aided start

5

 

< 3 sec. 

 

Warm start

6

 

< 30 sec. 

 

Cold start

7

 

< 35 sec. 

 

 

 

Interface protocol: 

NMEA 0183 v3.01 with GGA, VTG, GLL, GSA, GSV and RMC. 

                                                      

1

 Depends on accuracy of correction data provided by the SBAS service. 

2

 All satellites at -130 dBm. 

3 Time to get a fix when signal has been blocked for a short period of time. 
4 The GPS has been powered down for less than 2 hours and the stored position and time are valid. 

5

 The GPS has valid A-GPS information.  A-GPS is currently unsupported in the standard firmware. 

6

 The GPS has been powered down for more than one hour, but has stored information about its current 

position and time. 

7

 The GPS has no valid navigation data. 

Summary of Contents for M2M CONTROL C660

Page 1: ...Infranet Technologies GmbH Tempowerkring 19 21079 Hamburg Germany Fon 49 40 696 47 260 support m2mcontrol de M2M CONTROL C660 Technical Manual Version 2 0 ...

Page 2: ...uding 2004 104 EC UN ECE R10 edition 3 and CE mark The advanced power management features on the M2M Control C660 combined with the on board high capacity Li Ion battery allows the unit to stay in power saving mode for a longer period of time still being connected to the GSM network and capable of waking up on for example GSM activity change of digital inputs or a vibration sensor For demanding ap...

Page 3: ...ta flash logger memory with a capacity of 8 5 MB Internal 8 MB FAT32 flash drive Standard FAT32 SD CARD reader with up to 32 GB capacity 2 x RS232 channels and 1 x RS485 channel 2 x analog inputs with 0 10 volt 12 bit precision 5 x digital inputs and 4 high power solid state digital outputs Full CAN 2 0B controller with hardware filtering and multi speed support 1 Wire bus for accessories such as ...

Page 4: ...M2M CONTROL C660 Technical Manual V2 00 www m2mcontrol de support m2mcontrol de Page 4 of 36 THIS PAGE IS INTENTIONALLY LEFT BLANK ...

Page 5: ...e output 18 3D movement sensor 19 LED Indicators 20 User LED A and B 20 System LED S1 and S2 21 Switches 22 DIP switch 22 System switch RST 22 Internal Li Ion battery 23 Internal External SIM card readers 24 Installing the external SIM card 24 Installing the internal SIM card 25 SD CARD reader 25 Approved SD CARDs 25 Installing the SD CARD 26 Antennas 27 Cellular 27 GNSS 27 Device identification l...

Page 6: ...M2M CONTROL C660 Technical Manual V2 00 www m2mcontrol de support m2mcontrol de Page 6 of 36 Graphical view ...

Page 7: ...y for installation 4 pin X1 power and ignition 6 pin X4 for RS232 Programming 12 pin X2 for different communication interfaces and a 16 pin X3 for analog and digital I O Connection to the GSM antenna is via a SMA female and connection to a 3V active GNSS antenna is done via the SMB male connector Both antenna connectors are located on the back panel A graphical overview of the front and back are s...

Page 8: ...l 6 RS485 RS485 inverting signal 7 1W LED 1 Wire ID Button LED 8 SGND Signal Ground 9 CAN L CAN bus L signal 10 SGND Signal Ground 11 SGND Signal Ground 12 DC Out 3 3V 150mA DC Out for external equipment Shared with X4 Connector X3 16 pin I O connector overview Pin Name Description 1 DOUT 1 Digital output 1 2 DOUT 3 Digital output 3 3 DIN 1 Digital input 1 4 SGND Signal Ground 5 DIN 3 Digital inpu...

Page 9: ...TS Request To Send Accessories for cable assembly Order code Name RT O TYCO H4 TYCO p n 794617 4 Tyco Connector house 4 pins Bag with 10 pcs RT O TYCO H6 TYCO p n 794617 6 Tyco Connector house 6 pins Bag with 10 pcs RT O TYCO H12 TYCO p n 1 794617 2 Tyco Connector house 12 pins Bag with 10 pcs RT O TYCO H16 TYCO p n 1 794617 6 Tyco Connector house 16 pins Bag with 10 pcs RT O TYCO CR TYCO p n 7946...

Page 10: ...supply lines will destroy the internal GND connection For avoidance of such a scenario a fuse can be installed on the positive supply The C660 also contains an internal high capacity backup battery which will supply the C660 if the external power supply fails or is disconnected By default the C660 is powered down when a power fail occurs This setting however can be changed Please consult the M2M C...

Page 11: ... fail would also affect the digital outputs The C660 unit offers very advanced power management which makes it possible to have one or more outputs enabled while the C660 is in low power mode Please consult the M2M CONTROL IDE on line help for more information X3 16 pin I O connector overview Pin Name Description 1 DOUT 1 Digital output 1 9 DOUT 2 Digital output 2 2 DOUT 3 Digital output 3 10 DOUT...

Page 12: ... input So any logical level applied to this input must be greater than 2 ms to be valid The DIN 5 IGN input is available on both the X1 power connector and the X3 connector together with the other digital inputs only one should be used at a time The power management allows the possibility to configure a wake up on one or more digital inputs with individually configured falling or rising edge detec...

Page 13: ...urther details The input signal is connected between AINx and AGND AGND must be connected to the reference of the connected equipment Please be aware that deviations may occur as the system is very noise sensitive Avoid long unshielded wires and high current fast changing signals routed parallel to the analog signals The inputs are low pass filtered ESD and transient protected X3 16 pin I O connec...

Page 14: ...RD Receive Data for serial port 1 RS232 compatible 2 RS DET Programming cable detect normally unconnected if programming cable connect to GND 5 SGND Signal Ground RS232 port 2 The port is a general purpose RS232 port with all control signals according to EIA 561 that defines RS232 on a modular connector The signals are available on the RJ 45 connector located on the front panel of the C660 Connect...

Page 15: ...o the RS485 bus The maximum cable length for the RS485 bus is according to EIA TIA 485 A standard max 1200m 100kbit this limit is highly influenced by the quality of the cable signaling rate noise etc At longer cable lengths noisy environments or high communication speed it might be necessary to terminate the transmission line with a 1201 ohm resistor between terminal RS485 and terminal RS485 at e...

Page 16: ...ference If the C660 is connected to a non existing network a 1201 ohm resistor must be connected between CAN H and CAN L on each end of the transmission line in order to terminate it and avoid signal reflections Be aware that connecting the C660 to a CAN network can be dangerous If the C660 is not configured with the correct network parameters it will lead to network corruption and may interfere w...

Page 17: ...connector overview Pin Name Description 1 1Wire 1 Wire bus 7 1W LED 1 Wire ID Button LED 2 SGND Signal Ground Specification of the 1 Wire bus Max Unit Total weight1 65 m DC Out A 3 3V DC output is available on the X2 connector It is possible to control the output in order to save power The output is short circuit to ground ESD and transient protected Make sure not to exceed the current specificati...

Page 18: ...ker The microphone signal is biased internal for active microphones 4 pin headset connector overview Pin Name Description 1 Mic Microphone positive Input 2 SPK Speaker positive output 3 Mic Microphone negative input 4 SPK Speaker negative output Microphone characteristics Parameter Min Typ Max Unit Working voltage 1 65 1 8 1 95 V Working current 20 1000 µA Speaker characteristics Parameter Min Typ...

Page 19: ...e in 3 directions X Y Z with a force as high as 16g The simplest use is with the power management detecting when the vehicle is moved and the most advanced analytical applications such as driving behavior eco driving Please consult the M2M CONTROL IDE documentation for more detailed information The positions of the 3 axis is as following Specification Unit Resolution 16 g The acceleration can be s...

Page 20: ...emaining two LED s S1 and S2 are signaling the status and possible errors of the C660 unit User LED A and B LED A and B are composed of four individually controllable LEDs LED named A on the front consists of LED 1 green and LED 2 red LED named B on the front consists of LED 3 green and LED 4 red They are easily accessed from within the application program and it is possible to mix the LED s to ob...

Page 21: ... nicht definiert The unit is executing the application program while charging the internal back up battery Fast blinking redFehler Textmarke nicht definiert A runtime error has been detected in the program Use the M2M CONTROL IDE to obtain the fault log Alternating Fast Slow redFehler Textmarke nicht definiert The unit has lost its firmware This can only happen if during a firmware upgrade the C66...

Page 22: ...approx 2 mm for example a straightened out paper clip for this purpose By activating the switch shortly the C660 unit will do a complete reset as if the power was removed and reapplied If the reset switch is held down for approx 3 seconds1 the unit will enter recovery mode2 where the application will not be started In recovery mode the system will automatically turn on the GSM module to establish ...

Page 23: ... for the next power fail A maintenance charge will start every 20 days after the last charge This is to compensate for the battery self discharge etc By default the battery cannot be charged above 45 C or below 0 C The C660 offers charging down to 10 C using a specialized algorithm to protect the battery If the temperature is above 45 C the charging will not start and will be postponed until it is...

Page 24: ...contact to M2M Control for information on this option Installing the external SIM card The SIM card reader has a push push eject system and a mechanical lock for secure installation of the SIM card Orientate the card as shown below and insert it into the card reader Push the card into the reader until a click sound occurs the card will now stay in its position It might be necessary to use a small ...

Page 25: ...has been approved and tested by M2M Control The following Commercial Grade SD CARDs from Sandisk have been approved for use Capacity Sandisk SKU 4GB SDSDB 004G B35 8GB SDSDB 008G B35 16GB SDSDB 016G B35 32GB SDSDB 032G B35 Commercial grade SD CARDs can be used in applications where the limited write endurance is acceptable for example if the SD CARD is often replaced Commercial grade SD CARDs shou...

Page 26: ...al SLC Flash Advanced Wear Leveling 80 000GB or 2 800 000 writes 5 740 days or 15 7 years Commercial Grade Grade A MLC 2 bits per cell Advanced Wear Leveling 4 000GB or 140 000 writes 280 days Installing the SD CARD To insert a card into the reader orientate it as shown below and push the card into the reader until a click sound occurs Remove the card by pushing it into the reader until it clicks ...

Page 27: ... supports GPS GLONASS and QZSS so a suitable GNSS antenna must therefore be used The connection is with an SMB Male connector and the GNSS antenna must be a 3V active antenna with a SMB Female connector When installing the antenna please make sure that the antenna has a reasonable view of the sky so that it can receive the weak signals from the satellites Please also consult the installation guide...

Page 28: ... in wait for event 9 6 3 mA Resume on RS232 port 1 Unit in wait for event 10 7 4 mA Resume on RS232 port 2 Unit in wait for event 25 16 7 mA Resume on GSM activity Note Measured at TA 25 C If the external power source is removed and the internal battery is enabled the power consumption from the battery will be as listed below Maximum power consumption Unit running on internal battery Battery Unit ...

Page 29: ...et reference parameters 148 dBm Time To First Fix2 Autonomous Operation in Standard Sensitivity Mode Reacquisition3 1 sec Hot Start4 1 sec Aided start5 3 sec Warm start6 30 sec Cold start7 35 sec Interface protocol NMEA 0183 v3 01 with GGA VTG GLL GSA GSV and RMC 1 Depends on accuracy of correction data provided by the SBAS service 2 All satellites at 130 dBm 3 Time to get a fix when signal has be...

Page 30: ...ed only in an ESD safe environment Avoid touching the electronics components and parts 1 Remove the back panel Use a Torx TX10 screwdriver to remove the two screws 2 Gently pull out not all the way the electronic board so it is exposed Hint Use a finger to push on the RJ45 connector on the opposite end For assembling please follow the above steps backwards In any case DO NOT USE FORCE If difficult...

Page 31: ... a lid based type with a mechanical lock to secure a safe installation 1 Open the hinged lid of the reader and orientate the SIM card as shown below 2 Insert the SIM card into the lid of the card reader 3 Close the lid and slide the metal locking mechanism to the locked position 4 Assemble the unit again To remove the card slide the metal locking mechanism to the unlocked position as shown with an...

Page 32: ...M2M CONTROL C660 Technical Manual V2 00 www m2mcontrol de support m2mcontrol de Page 32 of 36 SIM card orientation SIM inserted and locked Lock Open ...

Page 33: ...served to prevent interruption of the communication By default reading from the CAN bus is enabled and writing to the CAN bus is disabled Installing jumper JP901 and thereby enabling the CAN bus Write capability of the unit is done on the sole responsibility of the user M2M Control can not be held responsible for any problems or damage due to the decision to enable the CAN bus Write capability The...

Page 34: ...M2M CONTROL C660 Technical Manual V2 00 www m2mcontrol de support m2mcontrol de Page 34 of 36 3 Install the jumper as shown above 4 Mount the end panel and secure it with the screws ...

Page 35: ...M2M CONTROL C660 Technical Manual V2 00 www m2mcontrol de support m2mcontrol de Page 35 of 36 M2M Control C660 Specifications Technical data are subject to changes ...

Page 36: ...M2M CONTROL C660 Technical Manual V2 00 www m2mcontrol de support m2mcontrol de Page 36 of 36 ...

Reviews: