S2: System LED2 pattern overview (Cellular activity and “Wait For Event”)
Pattern
Operating Status
Off
The cellular engine is turned off
600 ms On / 600 ms Off green
Missing SIM card or PIN code.
Network search and logon in progress.
75 ms On / 3 s Off green
Logged on to the network.
75 ms On / 75 ms Off /
75 ms On / 3 s OFF green
A Packet/GPRS session is active.
Flashing green
Indicates Packet/ GPRS data transfer.
On green (and all other LEDs OFF) The system is booting into recovery mode
10 s OFF / 50 ms ON green
(and all other LEDs OFF)
The RTCU device is in low-power “Wait For Event” state.
Switches
DIP-switch
The M2M CONTROL CX660 device contains two dip-switches. The dip switches are located on the
front side of the device for easy user access (see graphical overview).
System switch (RST)
The M2M CONTROL CX660 device contains a combined reset/diagnostic switch. This switch is
accessible from the front of the unit (see graphical overview). It is necessary to use a small thin
object with a diameter of approx. 2 mm, for example, a straightened-out paper clip for this
purpose.
By activating the switch shortly, the device will do a complete reset as if the power was removed
and reapplied.
If the reset switch is held down for approx. 3 seconds
1
the device will instead enter recovery mode
2
where the application will not be started. In recovery mode, the system will automatically turn on
any communication channel and establish a connection to the M2M Control GPRS Gateway or
M2M Communication Hub (if configured).
Pressing reset will also activate the device when in power-down mode. If external power is
removed and the backup battery is disabled, the reset switch can still be used to boot into recovery
mode, as long as there is enough power left on the battery.
5 System LED S2 will flash green three times when this state is entered.