M2M Control CX660 Technical Manual V1.02
Advanced Automotive M2MI/IoT Gateway
Page 36 of 44
The table below shows detailed information about the typical power consumption for the M2M
CONTROL CX660 device when it is in power-saving modes.
The following power-saving modes are used:
•
Mode 1:
LED blinks every ~10 s, resumes the application when it is awoken.
•
Mode 2:
Does not blink, resumes the application when it is awoken.
•
Mode 3:
Does not blink, resets the device when it is awoken.
See the M2M CONTROL IDE on-line manual for information about how to use the power saving
modes.
Power consumption: Device operating in power-saving modes
Mode 1
Mode 2
Mode 3
Wake-up source:
12V
24V
BAT
12V 24V BAT
12V
24V
BAT
Cellular
20
10
50
-
-
-
-
-
-
mA
CAN 1
4.5
2.5
15
-
-
-
-
-
-
mA
CAN 2
8.5
4.5
24
-
-
-
-
-
-
mA
RS232 1
mode 0 / 1
4.5 / 4
2.4 / 2.2 14 / 13
-
-
-
-
-
-
mA
RS232 2
mode 0 / 1
5 / 4.5
2.7 / 2.5 15 / 14
-
-
-
-
-
-
mA
RS485
4.5
2.5
14
-
-
-
-
-
-
mA
Time
1.1
0.7
2.9
0.7
0.4
1.6
0.4
0.3
0.7
mA
Din 1-5
1.1
0.7
2.9
0.7
0.4
1.6
0.4
0.3
0.75
mA
Power Failure
1.1
0.7
2.9
0.7
0.4
1.6
0.4
0.3
0.75
mA
Power Apply
1.1
0.7
2.9
0.7
0.4
1.6
0.4
0.3
0.75
mA
Vibration
1.2
0.7
3.2
0.7
0.4
1.9
0.5
0.5
1.1
mA
Note:
If wake-up on both power fail and power apply are enabled, mode 2 and 3 are not
supported.
Note:
Power consumption was measured from a fully charged battery.
Note:
The RS232 ports have support for two different wake-up configurations. Mode 0 will wake
on valid data while mode 1 will wake on any change on the interface.
Note:
The power consumption for CAN 1 has been measured with write disabled.