Basic Rules for Safety 

 

USE 

 

The infraNOMIC Heating Panels are designed only for use as heaters and are suitable for installation on walls 
in domestic rooms which are suitable for their installation. This heater must be installed inside buildings only. Do 
not store or install in outdoor areas. To use these heaters correctly it is necessary to follow the guidelines and 
instructions laid down in this document. 
 
DO NOT use the heaters in rooms that are open to the elements and/or rooms which could be subjected to the 
ingress of running water. 

 

Danger for children and persons with disabilities 

 

-  This appliance is not intended for use by persons (including children) with reduced physical, sensory or 

mental capabilities, or lack of experience and knowledge, unless they have been given supervision or 
instruction concerning use of the appliance by a person responsible for their safety. 

-

  Children must be supervised to ensure that they do not play with the appliance. 

-

  Make sure that the packing material is kept away from babies and small children as suffocation can result if 

placed over their mouths or noses. 

 

Electrical safety 

 

-

  Connect and run the heater according to the advice given on the specification plate on the rear of the heater. 

Only connect the heater to a 120 V AC supply grid. 

-

  To provide continued protection against risk of electric shock, connect to properly grounded outlets only! The 

outlet must be secured with 15 amperes. 

-

  Check each heater for damage before installation. Make sure that the heater itself; its plug and cable are free 

of any visible signs of damage. 

-

  Warning: The heater must not be used if the glass panel is damaged. If damage is noticed, immediately 

disconnect the panel from the power supply and contact our service department. 

-

  Do not pull, clamp or in any other way damage the connecting cable attached to the panel. 

-

  If the supply cord is damaged, it must be replaced by the manufacturer to avoid a hazard. 

-

  Do not attempt to carry out any repairs, changes or modifications to the heater. 

-

  Before any assembly or cleaning work is carried out, disconnect the panel from the electrical power. 

-

  Do not immerse the heating panel in water or splash water onto it! 

-

  When installing the panel in any form of wet room, it and its cabling should be situated well out of reach of any 

person using the shower or bath. Do not install the panel near of a bath, shower or swimming pool. 

-

  The installation of these panels in wet rooms should always be carried out by competent electricians who are 

completely aware of the specifications for installing electrical equipment in these types of room according to 
their own countries laws and standards. 

 

Product Safety Notes 

 

-

  Warning: This heater is not equipped with a device to control the room temperature. Do not use this heater in 

small rooms when they are occupied by persons not capable of leaving the room on their own, unless 
constant supervision is provided. 

-

  To avoid overheating, do not cover the heater. 

-

  Make sure the heater is not located immediately below a socket-outlet. 

-

  Do not rest anything against, or use the heating panel to dry clothes and/or stick anything onto its surface. 

-

  Make sure that all local objects in the immediate vicinity of the heater are a minimum of 20 inch (50,8 cm) 

away from the front and sides of the panel and 4 inches (10,16 cm) away when objects are above. 

-

  Make sure when installing the heater that the minimum distance of 0,8 inch (2 cm) between the Wall and the 

Panel is adhered too. This distance insures that enough space is available for air circulation. 

 

 
 

 

 

 

Summary of Contents for US-64-M

Page 1: ...infraNOMIC usa LLC INFRARED HEATING PANELS Operating and Installation Instructions Installation instructions for framed models infraNOMIC usa LLC 10441 Washington Hwy Glen Allen Virginia 23059 USA 1 ...

Page 2: ...ost efficient way Please make sure that you use the heater exactly as per the following instructions the adherence to these instructions is a pre condition to the manufactures liability regarding any guarantee cases After completion please store these instructions in a safe place so that they can be used again if necessary and can be given to another user if the panel changes hands Contents Thank ...

Page 3: ...diately disconnect the panel from the power supply and contact our service department Do not pull clamp or in any other way damage the connecting cable attached to the panel If the supply cord is damaged it must be replaced by the manufacturer to avoid a hazard Do not attempt to carry out any repairs changes or modifications to the heater Before any assembly or cleaning work is carried out disconn...

Page 4: ...correctly WARNING Make sure that the packing material is kept away from babies and small children as suffocation can result if placed over their mouths or noses Installation WARNING Please read the section regarding Basic Rules for Safety and details involving the installation location the information regarding safe distances and the operation of the panel Please take note of the following additio...

Page 5: ...adhered too Measure the distance X between the slots and transfer this measurement to the wall where the panel is to be installed Use a Level to ensure that the marks for drilling are level Drywall Installation Drill each of the holes with a 5 8 hole drill thru the Drywall or use the enclosed Wood screws if mounted to a stud in the Wall On Masonry use the Anchor and Wood Screws Insert the Toggle b...

Page 6: ...the power consumption of the heater The power consumption of your heater is included in the information on the nameplate of the heater to be found on the back of the panel Tips for correct use When the heater is turned on at first it is possible that for a short while you may be aware of a distinct sweet smell This is not harmful to health and if present is caused by the vaporisation of silicon in...

Page 7: ...f all current models are listed in the Data Page see page 9 The units comply with the test requirements of the European Low Voltage specifications 2006 95 EG and the harmonised Product Standards EN 60335 1 and EN 60335 2 30 and are marked with a CE Conformity Label Warranty and Service The heating panels by infraNOMIC usa LLC come with a warranty period of 5 years after the purchase date If these ...

Page 8: ... kg 24 x 36 inch US 93 M 530 118 129 ft 11 12 m 24 2 lb 11 kg 24 x 48 inch US 76 M 700 172 193 ft 16 18 m 30 8 lb 14 kg 24 x 60 inch US 96 M 900 215 236 ft 20 22 m 33 lb 15 kg More sizes later Frameless SL Power Size of room to be heated Metal Backing X Size w x h Model Watt approx Weight Due to the nature of tempered safety glass variations of the planetary may occur These values serve as a rough...

Page 9: ......

Reviews: