Supply and Parts Included

 

 

 

After being thoroughly tested at our works the heating panels are safely 
packed and dispatched with a reputable transport company. When your 
product arrives please check the outside appearance of the packing for any 
signs of damage. If you believe that the package is damaged in any way, 
please ask the delivery person to wait while you unpack it and check the 
state of the goods within for damage. 
If possible, keep the panels and accessories in the original packing until you 
decide to install the product. 
 
After unpacking the goods please check and make sure that all the following listed parts are included and are 
not damaged. 
 

-

  1 x Heating Panel with Cable (A) 

-

  1 x Accessory Set which includes: 

-

  2 x Hanging Plates (B) 

-

  4 x Bolts M6 x 8 (C) 

-

  2 x Bolts M6 x 25 (D) 

-

  2 x Mounting Screws & Anchor (E) 

-

  2 x Drywall Anchor & Washer  

-

  & tightening Nut(F) 

-  1 x Operating and Installation Handbook 
 
If you discover that any parts are missing or damaged, please contact the company where you purchased the 
product or contact our service department. 
 
 
The packing material is recyclable. Please make sure that this is disposed correctly. 
 

WARNING - Make sure that the packing material is kept away from babies and small children as 

suffocation can result if placed over their mouths or noses. 

 
Installation 

 

  WARNING 

Please read the section regarding ‘Basic Rules for Safety’ and details involving the installation location; the 
information regarding safe distances and the operation of the panel. 
Please take note of the following additional information regarding installation: 
 

-

 

The minimum dimension from the back side of the panel to the wall must be 0,8 inches (2 cm). This will 
always be the case if the items contained in the accessories are used. If other types of fitting systems are 
used our guarantee becomes null and void. 

-

 

The hot side of the heater is always the side with the sticker that says (Do not cover!) This sticker should 
always be visible after installation. 

-

 

Check before drilling holes that there are no electrical lines or water pipes hidden in the wall. 

-

 

Make sure that the power supply socket that you intend to use is within distance of the location of where 
you intend to install the panel 

– The cable attached to the panel is 6’ long. 

-

 

With Sheetrock hollow walls it may be necessary to use special expansion Bolts  

-

 

When the ‘Hooked Mounting Screws’ are screwed into the wall it is important that they are screwed in 
right up to the flange. 

 
 
 

 
 

 

 

 

 

Summary of Contents for US-64-M

Page 1: ...infraNOMIC usa LLC INFRARED HEATING PANELS Operating and Installation Instructions Installation instructions for framed models infraNOMIC usa LLC 10441 Washington Hwy Glen Allen Virginia 23059 USA 1 ...

Page 2: ...ost efficient way Please make sure that you use the heater exactly as per the following instructions the adherence to these instructions is a pre condition to the manufactures liability regarding any guarantee cases After completion please store these instructions in a safe place so that they can be used again if necessary and can be given to another user if the panel changes hands Contents Thank ...

Page 3: ...diately disconnect the panel from the power supply and contact our service department Do not pull clamp or in any other way damage the connecting cable attached to the panel If the supply cord is damaged it must be replaced by the manufacturer to avoid a hazard Do not attempt to carry out any repairs changes or modifications to the heater Before any assembly or cleaning work is carried out disconn...

Page 4: ...correctly WARNING Make sure that the packing material is kept away from babies and small children as suffocation can result if placed over their mouths or noses Installation WARNING Please read the section regarding Basic Rules for Safety and details involving the installation location the information regarding safe distances and the operation of the panel Please take note of the following additio...

Page 5: ...adhered too Measure the distance X between the slots and transfer this measurement to the wall where the panel is to be installed Use a Level to ensure that the marks for drilling are level Drywall Installation Drill each of the holes with a 5 8 hole drill thru the Drywall or use the enclosed Wood screws if mounted to a stud in the Wall On Masonry use the Anchor and Wood Screws Insert the Toggle b...

Page 6: ...the power consumption of the heater The power consumption of your heater is included in the information on the nameplate of the heater to be found on the back of the panel Tips for correct use When the heater is turned on at first it is possible that for a short while you may be aware of a distinct sweet smell This is not harmful to health and if present is caused by the vaporisation of silicon in...

Page 7: ...f all current models are listed in the Data Page see page 9 The units comply with the test requirements of the European Low Voltage specifications 2006 95 EG and the harmonised Product Standards EN 60335 1 and EN 60335 2 30 and are marked with a CE Conformity Label Warranty and Service The heating panels by infraNOMIC usa LLC come with a warranty period of 5 years after the purchase date If these ...

Page 8: ... kg 24 x 36 inch US 93 M 530 118 129 ft 11 12 m 24 2 lb 11 kg 24 x 48 inch US 76 M 700 172 193 ft 16 18 m 30 8 lb 14 kg 24 x 60 inch US 96 M 900 215 236 ft 20 22 m 33 lb 15 kg More sizes later Frameless SL Power Size of room to be heated Metal Backing X Size w x h Model Watt approx Weight Due to the nature of tempered safety glass variations of the planetary may occur These values serve as a rough...

Page 9: ......