SMT-BD2
Conformity with the standards:
CE
approval
- EMC standards
with multiaxis power supply configuration
Immunity: CEI standards 801- 2 - 3 - 4
BF rack and mains filter BF-35 or 70,
Conducted and radiated disturbances: EN 55011,
or SMTB.M 20 A single-axis rack and BF 35 filter.
Group 1, class A
"360°" shields; equipotentiality according to the
- Electrical standards for industrial machines:
wiring rules.
EN 60204.1: - Insulator
:
1500 VAC/1 min.
- Leakage current > 3 mA
(EMI filters)
Temperature range
* storage - 20°C to + 70°C
* operation 5°C to +40°C
From
40°C
on,
the
rated
currents
must
be
reduced
of
3
%/°C.
Max.
temperature:
50°C
1.2-C
URRENT RATINGS FOR THE
400
VAC
AMPLIFIER VERSION
Operating voltage
DC bus 565 VDC (480 VDC < DC bus < 685 VDC max.)
Auxiliary supply voltage
310 VDC ( 200 VDC < Uaux < 340 VDC max.)
Motor terminal to terminal output voltage
380Vrms for 565 VDC bus
Authorized output currents for
current pulse mode
operation (I
2
t protection in fusing mode)
AMPLIFIER
U rated
Imax (Arms)
Max. authorized rated current
(Arms) of the amplifier
(Vrms)
1 s
WITHOUT
FAN*
FAN TYPE
2*
SMT-BD2 - 400/15
400
15.5
5
7.5
SMT-BD2 - 400/30
400
30
8
15
SMT-BD2 - 400/45
400
48
10
19
SMT-BD2 - 400/60
400
60
not used
28
Authorized output currents for
continuous current mode
operation (I
2
t protection in limiting mode)
AMPLIFIER TYPE
U rated
Imax (Arms)
Max. authorized continuous
current (Arms) of the amplifier
(Vrms)
1 s
WITHOUT
FAN*
FAN TYPE
2*
SMT-BD2 - 400/15
400
15.5
not used
5
SMT-BD2 - 400/30
400
30
not used
10
SMT-BD2 - 400/45
400
48
not used
15
SMT-BD2 - 400/60
400
60
not used
23
* Maximum ambient temperature = + 40° C, fan 2 = 90 l/s.
Minimum inductance between phases
2 mH
Conformity with the standards:
CE
approval - EMC standards
with multiaxis power supply configuration
Immunity: CEI standards 801- 2 - 3 - 4
BF-400 rack and mains filter F400-35 or 70.
Conducted and radiated disturbances: EN 55011,
"360°" shields; equipotentiality according to the
Group 1, class A
wiring rules.
- Electrical standards for industrial machines:
EN
60204.1:
-
Insulator
:
2500 VDC/1 min.
- Leakage current > 3 mA
(EMI filters without condensators)
Temperature range
* storage - 20°C to + 70°C
* operation 5°C to +40°C
From
40°C
on,
the
rated currents must be reduced
of 3 %/°C.
Max.
temperature:
50°C
10
Chapter 2 – Specifications